Outdoor Natural Gas Barbecue Built-in Installation Specifications
Shut-Off Valve
1/2”-1/2” NPT
Access must be provided
to Shut-Off Valve.
NOTE:
When choosing a location for your Gas grill, keep in mind that it should not be located under
any overhead combustible construction. The side and bottom of the grill should not be any closer than
14 inches to combustible construction, and the back of the grill should not be any closer than 16 inches
to combustible construction.
Barbecues must be installed in accordance with AGA specifications and all local building codes.
Upper V
ent
Lower V
ent
NOTE :
Upper & lower ground-level vents (20 sq. in. minimum each)
MUST BE PROVIDED
for combustion air on both sides of built-in con-
struction. Please ask a Barbeques Galore associate for full details.
Figure 27
Louvers on BARBECUE must remain
unobstructed to allow for combustion air.
AGA Approved Natural
Gas Regulator
Gas Supply
1/2” Stainless
Flexline
Close Nipple
Outer lips of barbe-
cue rests on edges.
Non-combustible
Construction
- 16 -
n
WARNING
Vapors from products containing Chlorine and other caustic chemicals can
cause Stainless Steel flexible connectors to corrode. THESE PRODUCTS
SHOULD NOT BE STORED IN AN ISLAND OR NEAR THE connector.
Cleaning solutions, Household Chemicals and Solder fluxes can also cause
pinholes if they come in contact with these connectors and
MUST
be
washed off immediately with water.