5
Safety, Assembly & Instruction Manual 5
E. PRECAUTIONARY LEAK TEST
LEAK TESTS MUST BE CARRIED OUT IN A WELL VENTILATED AREA
•
Confirm all control knobs are in the
‘OFF’
position.
•
Open the gas control valve on the gas cylinder.
•
To check for gas leaks a solution of soapy water is required (50% water and 50% soap)
NEVER USE AN OPEN FLAME TO CARRY OUT A GAS LEAK TEST
•
The gas piping system
MUST
be checked for leaks by brushing the soapy water solution across
each joint including valve connections, hose connections, side burner connections and regulator
connections.
•
If bubbles appear across any joint or connection there is a leak:
o
Immediately turn the cylinder gas valve
‘OFF’.
o
Check and retighten all gas connections and joints.
o
Repeat from the start of section
5E PRECAUTIONARY LEAK TEST.
o
If the leak has been corrected then the barbeque can be used.
o
If the leak has not been fixed
DO NOT USE YOUR BARBEQUE,
contact the after sales
support service provider as listed at the end of this manual.
IT IS RECOMMENDED THAT A LEAK TEST BE CARRIED OUT ON A YEARLY BASIS
CHECK GAS CYLINDER CONNECTION WHEN EXCHANGING GAS CYLINDER