23
UNILUX-6 40
Installation instructions
3.3.3
Fitting in an existing chimney
Do not use masking tape on the appliance when
installing and plastering.
Tape can damage the fi nish of the appliance.
•
Remove the existing fi
re basket or stoking stones and remove the shut-off fl ap.
The chimney must be intact and must not be damaged during fi tting.
The chimney breast opening must be big enough for a gap of 1 - 3 cm to be left all
round the appliance. Clad the chimney breast opening from the inside with a ceramic
wool fi reblanket or similar (see section 3.3).
•
Extend the existing chimney so that it ends at the appliance’s smoke outlet. To do
this, use a fl exible, double-walled stainless steel chimney, for example.
•
Slide the appliance into the chimney breast opening. Seal the smoke outlet where it
joins the chimney so that no soot can accumulate above the appliance
under any
circumstances
.
See 3.3.4.
•
Level off the appliance so that the cover does not catch on the base.
• Fill any gaps around the appliance with a ceramic insulation wool fi reblanket and
position the frame (where supplied)
.
3.3.4 Fitting in a newly-built chimney
Do not use masking tape on the appliance when
installing and plastering.
Tape can damage the fi nish of the appliance.
• Clad the appliance on the top, sides and rear up to the front edge with an approx.
10 cm thick ceramic isolation wool fi reblanket. Leave a few centimetres clearance
between the front of the chimney and the appliance.
• Level off the appliance.
• Make a good seal between the smoke outlet from the appliance to the chimney.
See also 3.3.5.
Ensure that the entire fl ue is gas-tight.
Содержание UNILUX-6 40
Страница 2: ......
Страница 4: ...4 UNILUX 6 40 Installation instructions...
Страница 6: ...6 UNILUX 6 40 Installation instructions...
Страница 35: ...35 UNILUX 6 40 Installation instructions 7 DIMENSIONS 7 1 without frame...
Страница 36: ...36 UNILUX 6 40 Installation instructions 7 2 with built in frame...
Страница 37: ...37 UNILUX 6 40 Installation instructions 7 3 with classic frame...
Страница 38: ...38 UNILUX 6 40 Installation instructions 7 4 45 with classic frame...
Страница 39: ...39 UNILUX 6 40 Installation instructions 7 5 with deepened frame...
Страница 43: ......
Страница 44: ...04 120619 340654 Uw Barbas dealer...