55.3.6
Insulate the appliance
Caution:
• Use white unbound ceramic insulation wool. Do not use glass wool or rock
wool, these materials can cause a bad smell, unwanted smoke and is not
applicable for high temperatures.
Table 5: Ceramic insulation wool requirements
Temperature resistance
> 700 °C
Density
> 80 kg/m
3
• Put a ceramic wool blanket with a thickness of at least 5 cm on the top of the
appliance and the sides and back of the appliance.
• Keep approximately 10 cm free between the front of the appliance and the front of the
fireplace.
5.3.7
Build the fireplace
Caution:
• If the appliance is placed against a load-bearing wall or a combustible wall,
put a non-combustible insulating wall with a thickness of at least 100 mm
and a thermal conductivity of maximum 0.10 W/m.K before it on a distance
of at least 20 mm from the combustible or load-bearing wall.
Table 6: Installation against combustible or load-bearing walls
Item
Description
A Appliance
B Air gap
Space between appliance and insulation plate. Width of air gap at
least 3 mm
Installation
Falcon 59/70
21
Содержание Falcon 59/70
Страница 1: ...I Installation and maintenance manual Falcon 59 70 Serial number Production date...
Страница 27: ...Annual maintenance Falcon 59 70 2 27...
Страница 31: ...8 8 Dimensions 8 1 Frameless appliance Dimensions Falcon 59 70 31...
Страница 33: ...8 8 3 Appliance with 3 sided classic frame Dimensions Falcon 59 70 33...
Страница 34: ...8 8 4 Appliance with 4 sided classic frame Dimensions 34 Falcon 59 70...
Страница 37: ...Warranty Terms Falcon 59 70 3 37...
Страница 38: ...Warranty Terms 3 38 Falcon 59 70...
Страница 39: ...Warranty Terms Falcon 59 70 3 39...
Страница 40: ...Y Your Barbas dealer 001 14 06 2018 347339...