3
Safety
3.1
Safety devices on the appliance
Name
Description
Thermo-electric pilot light shut off
Prevents unforseen discharge of gas from the main
burner.
Overpressure hatch
If an overpressure occurs in the appliance, the hatch
opens for a short duration. When the hatch opens, a
loud noise can occur. If an overpressure occurs, the in-
staller must do a thorough check on the appliance.
Overpressure door
(Only on 'Floating Frame (+)' door)
If an overpressure occurs in the appliance, the door
opens for a short duration. When the door opens, a
loud noise can occur. If an overpressure occurs, the in-
staller must do a thorough check on the appliance.
3.2
Safety instructions for installation
Warning:
• The appliance must be positioned and connected as a 'room sealed
system' appliance by a certified and registered gas installer.
• Before beginning the installation, check that the details on the rating plate
correspond to the gas type and supply pressure to which the appliance will
be connected.
• Install the appliance in accordance with the following installation
instructions, and the national and the local applicable regulations.
• Do not put flammable materials in the appliance.
• Make sure that the area around the appliance is free of flammable
materials at all times. the minimal safe distance is 100 cm from the
appliance.
• Make sure that the burner openings stay clean during installation.
Blockage of the burner openings can lead to a dangerous situation.
• Make sure that the gas regulator block and the piping remain free of
cement or other building material. Otherwise, the gas regulator block or the
piping can start to leak.
• Do not twist the flexible pipes to the gas regulator block. Make sure that
there is no stress on the flexible pipes and the gas regulator block.
• Make sure that you do not damage the pipes.
• Make sure that the compression fittings do not come loose.
• Do not put the appliance directly against a flammable or non-flammable
wall.
• Make sure to protect a flammable floor under the intended position of the
appliance with a plate of non-flammable material that extends the full width
and depth of the appliance.
• After installation, make sure that the pipes and compression fittings are
gas tight.
Safety
20
Gas Fire Front 90-60
Содержание 90-60 PF2
Страница 10: ...2 5 Overview of the ceramic log set Figure 3 Overview of ceramic log set Description 10 Gas Fire Front 90 60...
Страница 60: ...3 Slide the strip downwards 4 Tighten the nut wings Maintenance 60 Gas Fire Front 90 60...
Страница 61: ...5 Tilt the top panel upwards 6 Install the front panel and side panels Maintenance Gas Fire Front 90 60 61...
Страница 70: ...9 Dimensions 9 1 Gas Fire Front 90 60 PF2 with Floating Frame Gas connection Dimensions 70 Gas Fire Front 90 60...
Страница 71: ...9 2 Gas Fire Front 90 60 PF2 with Floating Frame Gas connection Dimensions Gas Fire Front 90 60 71...
Страница 74: ...9 5 Gas Fire Front 90 60 PF2 with Hidden Door Gas connection Dimensions 74 Gas Fire Front 90 60...
Страница 75: ...9 6 Gas Fire Front 90 60 PF2 with Hidden Door Gas connection Dimensions Gas Fire Front 90 60 75...
Страница 78: ...9 9 BARBAS Airbox 160 with 4 insert models Dimensions 78 Gas Fire Front 90 60...
Страница 79: ...9 10 BARBAS Airbox 320 with 4 insert models Dimensions Gas Fire Front 90 60 79...
Страница 82: ...11 EU Declaration of Conformity EU Declaration of Conformity 82 Gas Fire Front 90 60...
Страница 83: ...EU Declaration of Conformity Gas Fire Front 90 60 83...
Страница 84: ...Your Barbas dealer 002 21 07 2022 352517 251 002...