OB Burners – Unpacking and Setup – Manual Valve Systems
.
STEP 1:
Insert Burner Orifice into mixing sleeve and attach Orifice
Retainer Bracket with [2] 1/2” DT Screws. Then insert Electrode Mount
Plate and Sparker into Burner and install with [2] 1/2” DT Screws.
STEP 2:
Install Burner with attached Valve
System into structure.
For Outdoor Fire Tables (OFT) refer to
OFT Burner Installation Instructions
.
For Outdoor Fireplaces (OFP) refer to
OFP
Burner Installation Instructions
.
Refer to
Custom Enclosures
Section for
Custom Enclosures.
NOTE:
Filler Strips must be installed
before media is placed into burner.
STEP 3:
Assemble Igniter, add battery (not
included) and attach to valve bracket with
[2] DT Screws.
Parts List: OB24 / OB36 / OB48 MAP/MAN
[1]
Burner, c/w [1] Pilot Shield, [2] Ends, [3] Filler Strips
[1] Manual Valve (c/w Regulator & 5ft Hose for LP Systems)
[1] Push Button Igniter c/w wire and Sparker
[1] Igniter Mount Plate
[1] Valve Key
[1] Key Way Installation Tool
[1] Brass Orifice for NG Conversion (LP Systems)
[1] Tank Retainer (LP Systems)
Hardware Bag:
[10] 1/2” DT Screws, [4] #6 Black Screws, [2]
#10 Woodscrews
[3] Filler Strips (See Below)
Orifice Retainer
Bracket
Electrode Mount Plate
and Sparker
24OB – 23-9/16”
36OB – 35-9/16”
48OB – 47-9/16”
24OB – 10-5/8”
36OB – 10-5/8”
48OB – 10-5/8”
24OB – 10-5/8”
36OB – 22-5/8”
48OB – 34-5/8”
FILLER STRIPS:
Long Flange Up
Short Flange Down
Qty [4] 1/2” DT Screws
to attach Valve
NG Conversion Orifices
(Included with MAP Burners)
OB24MAP - #40
OB36MAP - #31
OB48MAP - #30
Air Shutter = 1/16”- NG
Air Shutter = Full Open- LP
Igniter
Mount
Plate
Assemble Igniter and
attach to Valve
10
Содержание OB24MAP
Страница 46: ...Gas Conversion for Modulator PART C 46...