D-Fly – Programming Guide v1.2
- 48 -
Data Capture
for Workforce
in Motion
Modifier Characters
The modifier character is determined by summing the option values of each symbology. If the sum is greater
than 9, use A, B, C, D, E , F in the place of 10, 11, 12, 13, 14 and 15.
Code 39 Option Values
0
No check character or Full ASCII
1
Reader has performed mod 43 check
2
Reader has performed mod 43 check and stripped the check character
4
Reader has performed Full ASCII conversion
Telepen Option Values
0
Full ASCII mode
1
Double density numeric mode
2
Double density numeric followed by full ASCII
4
Full ASCII followed by double density numeric
Code 128 Option Values
0
Standard
1
Function code 1 in first character position
2
Function code 2 in second character position
4
Concatenation according to ISBT specification has been performed, and concatenated data follows.