background image

 

RS232 dongle Plug & Scan – Communication Protocol v3.27.1 

  - 5 - 

Data Capture 

for Workforce 

in Motion 

1.2.

1.2.

1.2.

1.2.

 

Generic packet 

The dongle will parse data respecting a specific format. 

 

1.2.1.

1.2.1.

1.2.1.

1.2.1.

 

RS232

RS232

RS232

RS232 

 

 

 

All the frames incoming to the RS232 dongle are formatted as shown: 

Header 

Code ID 

Length 

Payload 

4 bytes 

1 byte 

2 bytes 

N byte(s) 

Frames sent by the dongle via its RS232 link can have other formats. 

 

1.2.1.1.

1.2.1.1.

1.2.1.1.

1.2.1.1.

 

Header

Header

Header

Header 

 

 

 

The 4 bytes for the header are always the same: 3C 3A 3F 3E for “<:?>” 

 

1.2.1.2.

1.2.1.2.

1.2.1.2.

1.2.1.2.

 

Code ID

Code ID

Code ID

Code ID 

 

 

 

The Code ID, encoded on 1 byte, corresponds to the command to send. 

Cf. §2 for complete list of code IDs. 

 

1.2.1.3.

1.2.1.3.

1.2.1.3.

1.2.1.3.

 

Length

Length

Length

Length 

 

 

 

Depending on the selected code ID the payload length may vary (from 0 to 65535 bytes), its length is 

specified on the 2 bytes of the « length » field.  

 

1.2.1.4.

1.2.1.4.

1.2.1.4.

1.2.1.4.

 

Payload

Payload

Payload

Payload 

 

 

 

For the « get » commands, no payload is required since the dongle responds with the requested 

data. The specified length in the « length » field is then 0 and no byte constitute the payload. When 

the sent command is a « set » command, the dongle parses and treats the command if its format is 

correct but does not answer. 

 

 

1.2.2.

1.2.2.

1.2.2.

1.2.2.

 

Bluetooth

Bluetooth

Bluetooth

Bluetooth 

 

 

 

All the commands described in this document can also be sent via Bluetooth thanks to a Baracoda 

barcode scanner by scanning configuration barcodes 

Commands respecting the above format can be encoded into Code128 barcodes. 

 

 

 

2.

2.

2.

2.

 

Communication protocol 

2.1.

2.1.

2.1.

2.1.

 

Dongle to HOST messages 

Data coming from the dongle can have different formats depending on the mode it is running. 

Содержание BDRS01

Страница 1: ...RS232 dongle Plug Scan Communication Protocol Baracoda RS232 dongle Plug Scan Communication Protocol Baracoda TM August 2008 Data Capture for Workforce in Motion RS232 dongle Plug Scan...

Страница 2: ...N HISTORY 3 1 INTRODUCTION 4 1 1 GENERALITIES 4 1 2 GENERIC PACKET 5 1 2 1 RS232 5 1 2 2 BLUETOOTH 5 2 COMMUNICATION PROTOCOL 5 2 1 DONGLE TO HOST MESSAGES 5 2 1 1 GET VERSION 6 2 1 2 COMMAND RESPONSE...

Страница 3: ...Data Capture for Workforce in Motion Revision History Revision History Revision History Revision History Changes to the original manual are listed below Document Date Description 3 27 06 Aug 08 Initia...

Страница 4: ...232 enabled terminal The dongle allows a simple and secure Bluetooth connection just scan the connect barcode on the dongle and the scanner gets connected and ready to operate The dongle is compatible...

Страница 5: ...Length Depending on the selected code ID the payload length may vary from 0 to 65535 bytes its length is specified on the 2 bytes of the length field 1 2 1 4 1 2 1 4 1 2 1 4 1 2 1 4 Payload Payload Pa...

Страница 6: ...command except the Get Version command the dongle responds using the frame format described in 1 2 1 2 1 3 2 1 3 2 1 3 2 1 3 In In In In mode 0 Standard P mode 0 Standard P mode 0 Standard P mode 0 St...

Страница 7: ...to it Payload None Response None Code ID 0x08 Command Set prefix Description Defines and enable a prefix Payload 0 8 byte s prefix default none If no payload prefix is disabled Response None Code ID 0...

Страница 8: ...ts Payload 4 bytes Baud rate MSB Baud rate LSB Stop Bits Parity Bits Response None Available settings are Baud Rate Value Don t change 0x0000 9 600 default 0x0027 19 200 0x004F 38 400 0x009D 57 600 0x...

Страница 9: ...1 byte 0 Real Time without no data loss mode 1 Real Time with no data loss mode default 2 Batch mode if supported by scanner Response None Code ID Exception Command Reset dongle Description Resets th...

Страница 10: ...he connection when the auto configuration is done Payload 6 bytes The 6 bytes of the connected scanner s BDA Response None Event ID 0x01 Event Disconnection message Description This event is sent to t...