BAQ   kaloMAX NT II                                                                                      

Manual

5.6 Manage grinding parameters

5.6.1 Change parameters

Grinding speed, grinding path, dosage time and ball diameter can be changed 

in the main screen by pressing the corresponding function key or

by selecting the appropriate menu item in the sub-menu 

Grinding parameter / 

Edit

.

The unit in which the grinding speed and the grinding path have to be entered are 

determined in the system configuration (see chapter  5.8.1).

In any case, an input screen appears, where the value of the parameter can be 

changed.

5.6.2 Save parameter

Under the menu item 

Grinding parameter / Save

, the current grinding parameters can

be saved with a chosen name.

After selection of the menu item, a text input screen comes up where the user can 

enter the new data record name.

5.6.3 Load parameter

Under menu item 

Grinding parameter / Load

, it is possible to retrieve the stored 

grinding parameters.

Use the 

▲ and ▼

 cursor keys to select the required data record from the list of 

available grinding parameters and load it by pressing ENTER.

5.6.4 Delete parameter 

If a stored grinding parameter record is not required any more, it can be deleted under

menu item 

Grinding parameter / Delete

.

Page 20

Содержание kaloMAX NT II

Страница 1: ...High precision wear resistance tester kaloMAX NT II Manual...

Страница 2: ...ANING THE SHAFT 9 2 5 SPECIMEN 9 2 6 BALL 9 2 7 AUTOMATIC DOSAGE APPARATUS 9 2 8 FILLING THE CARTIGE WITH ABRASIVE SLURRY 10 2 9 DOSING PARAMETERS 10 2 10 MANUAL DOSAGE WITH A PIPETTE 10 3 TEST EXECUT...

Страница 3: ...P 18 5 4 MAIN SCREEN 19 5 5 MENU 19 5 6 MANAGE GRINDING PARAMETERS 20 5 6 1 CHANGE PARAMETERS 20 5 6 2 SAVE PARAMETER 20 5 6 3 LOAD PARAMETER 20 5 6 4 DELETE PARAMETER 20 5 7 CLEAN VALVE 21 5 8 SYSTEM...

Страница 4: ...ve slurry is applied onto a 100Cr6 steel ball with a diameter of 30mm This ball is rotating against a specimen see Figure The wear crater should be ground into the layer without breaking through to th...

Страница 5: ...nce by means of a high precision wear resistance tester Extensive measurements have been done at the FhG IST to characterize the influence of different climatic conditions temperature and humidity on...

Страница 6: ...ST and the quality of every 50ml cartridge is tested A reference layer is provided so you can check the quality at any time 1 4 Place of installation It would be best to place the device in an air con...

Страница 7: ...value depends basically on the thickness and wear resistance of the layer to test It is important that the depth of the resultant wear crater is not greater than the thickness of the functional layer...

Страница 8: ...rectly It depends on the weight and diameter of the ball the blade angle of the specimen and the distance between specimen and shaft Therefore it is recommended to keep this values constant for a seri...

Страница 9: ...e oil fingerprints etc 2 6 Ball The ball must be cleaned with ethyl alcohol The ball has to be free from abrasive slurry A thorough cleaning of the ball is recommended to avoid slipping at the contact...

Страница 10: ...d duration must be set Parameters for a drop with a mass of about 35 mg Pressure 0 45 bar Duration 150 ms The pressure is adjusted by a fine setting valve at the rear side of the device The duration c...

Страница 11: ...he laser pointer points to the spot on the surface of the specimen where the ball will grind the spherical cap The laser pointer will be switched on automatically when it has reached its final positio...

Страница 12: ...can be made The grinding craters should have a minimal distance of 1 2mm 3 4 Aborting a test A test should be aborted when the ball begins to tumble Probably a bit of the abrasive slurry has spread on...

Страница 13: ...r the calculation of the wear volume an ideal spherical cap is assumed The crater i e wear volume Vv can be calculated as follows h r 3 h 3 v 2 V where Vv Wear volume m3 h Crater depth m r Ball radius...

Страница 14: ...because the source units should be kept recognizable 4 3 Analysis by microscope For an analysis by microscope the diameter of the wear crater has to be measured 4 4 Calculation of the wear coefficient...

Страница 15: ...Pressing this key starts the grinding process see chapter 5 3 Start Stop Pressing this key during grinding stops the grinding process see chapter 5 3 Start Stop Otherwise the valve is cleaned see chap...

Страница 16: ...case a text input field opens In the upper field highlighted in white called text field hereafter the entered text is shown The previous lines show the characters that can be selected A space is repre...

Страница 17: ...aft RPM Grinding path m number of ball revolutions or number of shaft revolutions Dosage time of the abrasive slurry ms Diameter of the grinding ball Furthermore the following basic settings can be ma...

Страница 18: ...ll revolutions 13 UB 9200 UB Grinding path 1 2 m 870 m Number of shaft revolutions 20 US 15000 US Grinding ball diameter 12 mm 40 mm 5 3 Start Stop Press START on the main screen to start the grinding...

Страница 19: ...n Changing the parameters in the main screen has no effect on the stored parameters If no grinding operation is in progress the valve can be cleaned by pressing the STOP key 5 5 Menu Press ESC when th...

Страница 20: ...lue of the parameter can be changed 5 6 2 Save parameter Under the menu item Grinding parameter Save the current grinding parameters can be saved with a chosen name After selection of the menu item a...

Страница 21: ...ment is in progress when the STOP button is pressed this causes the measurement to abort 5 8 System settings Selecting System on the menu opens a sub menu with the following sub items Configuration Se...

Страница 22: ...alues 5 8 4 Information Under the menu item System Information the system information is displayed This information comprises the device serial number software version number kernel version and file s...

Страница 23: ...BAQ GmbH Hermann Schichting Str 14 38 110 Braunschweig Germany Tel 49 5307 95102 0 Fax 49 5307 95102 20...

Отзывы: