Bante821 Portable Dissolved Oxygen Meter 

14 

 

Communication 

Bante Instruments provides a Data Acquisition System that can be used to transfer data, receive the measuring values or import the data to Excel. You are 
able to download this software from our official website at 

www.bante-china.com

Before installation, ensure that Windows 7/8/10 operating system has 

been installed on your computer. 
 

Receiving data 

 

Connect the USB cable to meter and computer. Click the DAS icon, the system will automatically scan an available communication port and show the 

 

message box “Found a port on your computer”. 

 

 

Click the 

OK

 button, the application starts. 

 

 

 

 

Click the 

Connect

 

button, the screen shows “Port is connected” indicate that 

the communication between the meter and the computer has been 

 

established.   

 

Click the 

OK

 button to confirm. 

 

Click the 

Receive

 button, the stored data automatically transfer to computer. 

 

Interval recording 

This function is used for recording the measuring value within the specify time period. 

 

Click the 

Interval Recording

 button and select a time option. 

 

Click the 

Receive

 button, the measured value will automatically send to data sheet. 

 

   

 

The first data need 1 minute to be shown on screen. 

 

Do not press any key on meter during the Interval Recording mode, it will cause communication interruption. 

 

Graph mode 

This function is used for viewing the variations of the measured parameter continuously.   
Click the 

Graph

 button, the screen immediately shows the curve graph. To quit current mode, click the 

Back

 button. 

 

Create the excel file 

When the transfer is completed, click the 

Save as Excel

 button, the measured values in the data sheet will automatically convert to Excel file.   

 

 

Once the software is closed, all received data will be lost and can not be recovered. 

 

Содержание Bante821

Страница 1: ...Bante821 Portable Dissolved Oxygen Meter Instruction Manual BANTE INSTRUMENTS CO LTD...

Страница 2: ...urrent work environment meets following conditions Relative humidity is less than 80 Ambient temperature is greater than 0 C and less than 60 C No potential electromagnetic interference The following...

Страница 3: ...mode Stable icon Indicates the measuring value has stabilized Calibration mode icon Indicates the meter is in the calibration mode Hold icon Indicates the measuring value has been locked Setup mode ic...

Страница 4: ...key for 3 seconds Starts calibration Enters the setup menu Press and hold the key for 3 seconds Stores current reading to memory Increase value or scroll up through the menu item Views the data logs...

Страница 5: ...s using the DC5V power adapter with USB cable for power supply NOTE take out the batteries Filling the Electrolyte Solution 1 Take out the dissolved oxygen probe and electrolyte solution from the pack...

Страница 6: ...sensor cord Always make sure that the connector is clean and dry Switching the Meter On and Off Press the Meas key to switch on the meter the display shows the measured value Press and hold the Meas...

Страница 7: ...efault measurement units Degrees Celsius C mg L mmHg Degrees Fahrenheit mg L Milligrams per liter ppm Parts per million mmHg Pressure unit kPa Pressure unit Stability Criteria When the LO option is en...

Страница 8: ...isplay shows an option 1 3 Press the or key to select the desired option 1 4 Press the Enter key to confirm the meter returns to the measurement mode Setting is completed If you want to exit the setti...

Страница 9: ...9 577 700 92 8 696 2300 76 0 570 800 91 7 688 2400 75 0 563 900 90 5 679 2500 74 1 556 1000 89 4 671 2600 73 2 549 1100 88 3 662 2700 72 3 542 1200 87 2 654 2800 71 4 536 1300 86 1 646 2900 70 5 529...

Страница 10: ...leted DO Calibration in Saturation Mode The Bante821 dissolved oxygen meter is able to perform either 1 or 2 points calibration For single point calibration we recommend that you perform 100 saturatio...

Страница 11: ...Enter key to confirm Wait for the reading to stabilize the meter automatically shows END Calibration is completed Performing a percentage saturation calibration will simultaneously calibrate the corr...

Страница 12: ...or at least 10 minutes Press the Enter key the meter begins the calibration the Calibration icon continuously flashing 2 4 Wait for the reading to stabilize the display will show 8 25mg L CAL 2 the me...

Страница 13: ...t before measurement Some gas and steam such as chloride sulfur dioxide sulfureted hydrogen ammonium carbon dioxide and iodin can permeate the membrane via diffusion So their existence will influence...

Страница 14: ...s on the display Viewing stored readings 1 Press the MR key in the measurement mode the meter shows LOC P 01 Data Log 2 Press the Enter key the meter shows the serial number of the stored data 3 Press...

Страница 15: ...ished Click the OK button to confirm Click the Receive button the stored data automatically transfer to computer Interval recording This function is used for recording the measuring value within the s...

Страница 16: ...dirty or broken Electrolyte solution is depleted Refilling electrolyte solution Zero oxygen solution is contaminated Replace the calibration solution Keypad is not working properly Replace the batter...

Страница 17: ...dendum Preparation of the Zero Oxygen Solution Dissolve 500mg of sodium sulfate Na2SO3 reagent and a small amount of cobalt II chloride hexahydrate CoCl2 6H2O in the 250mL distilled water mix the solu...

Страница 18: ...to speed up these efforts Warranty The warranty period for meter is one year from the date of shipment Above warranty does not cover the sensor and calibration solutions Out of warranty products will...

Отзывы: