Bantam e-Station BC8HP Скачать руководство пользователя страница 18

Display

REVERSE POLARITY   

Display

CONNECTION BREAK  

Display

SHORT ERR  

Display

INPUT VOL ERR

Display

VOL SELECT ERR

Display

BREAK DOWN   

Display

BATTERY CHECK
LOW VOLTAGE   

Display

Display

BATTERY VOLTAGE
         CELL LOW VOL

Warning and error messages

The output is connected to a battery with incorrect polarity.

This will be displayed in case of detecting an interruption of 
the connection between battery and output or voluntarily 
disconnecting the charge lead during the operation of 
charge or discharge on output.

The voltage of one of the cell in the Lithium battery pack is 
too low. Please check the voltage of the cell one by one.

The voltage of Lithium battery pack was selected incorrectly. 
Verify the voltage of battery pack carefully.

The processor detects the voltage is lower than you set at 
Lithium program. Please check the cell count of the battery.

 BC8HP incorporates a various functions of protective and monitoring the system to 
verify functions and the state of its electronics. In any case of occurring error, the 
screen displays the cause of error that is self-explanatory with audible sound.

The processor detects the voltage is higher than you set at 
Lithium program. Please check the cell count of the battery.

Display

There are bad connection at the individual connector. 
Please check the connector and cables carefully.

Display

Display

TEMP OVER ERR

Display

CONTROL FAILURE

There was a short-circuit at OUTPUT. Please check the 
charging leads.

The voltage of input power drops below the limit.

There happens the malfunction at the charger circuit by any 
reason. The charger should be repaired at our factory.

The voltage of one of the cell in the Lithium battery pack is 
too high. Please check the voltage of the cell one by one.

The internal temperature of the unit goes too high. Cool 
down the unit.

The processor can not continue to control the feeding 
current by any reason. The unit needs to be repaired.

BATTERY CHECK
HIGH VOLTAGE   

BATTERY VOLTAGE
        CELL HIGH VOL

BATTERY VOL ERR
      CELL CONNECT

                                             

 

 

- 18 -

   

                                       

+

-

+

-

+

-

+

-

+

-

+

-

-

+

-

+

-

-

+

-

+

-

+

-

+

-

!

!

!

Содержание e-Station BC8HP

Страница 1: ...ssor controlled high performance rapid charger discharger with integrated balancer 280watts of charging power USB PC link and firmware upgrade Temperature sensor Charge current up to 12A discharge cur...

Страница 2: ...charge Lithium battery for special purposes Fast charge reduces the charging time of Lithium battery and Storage mode controls the final voltage of the battery to be suit for long time storage Maximu...

Страница 3: ...rge or discharge These data can be called back at any time you need and the process can be executed without program setting PC based analysis using USB communication For technical expert BC8HP offers...

Страница 4: ...ay be very hot and can cause a physical damage on your finger or body Be sure to understand the information of the battery to be charged or discharged accurately If the program is set up incorrectly t...

Страница 5: ...able to the unit first and only then to the battery to be charged or discharged Reverse the sequence when disconnecting Do not connect more than one battery pack to the charge lead at any one time Ple...

Страница 6: ...TYPE STOP TYPE STOP Capacity Cut off INC INC DEC DEC NiMH NiCd Pb Trickle charge Key Beep Buzzer 6 DEC DEC INC INC DEC DEC INC INC DEC DEC INC INC DEC DEC INC INC DEC DEC INC INC DEC DEC INC INC DEC D...

Страница 7: ...nished within the time term with the erroneous cell count This may cause the fatal result If the processor recognizes the cell count incorrectly at the beginning of charge or discharge process you may...

Страница 8: ...isplay NiMH NiCd Pb Trickle 100mA INC DEC DEC INC You can set the trickle charge mode on or off If it is on the charger will automatically supply the trickle charge current to achieve the full charge...

Страница 9: ...pe of batteries by number that represents the individual parameters They can be called back for the process of charging or discharging without setting up the program again Select the data number using...

Страница 10: ...The value on the left side of second line sets a charge current and the value on the right side sets the voltage of the battery pack In AUTO the charger will check the cell count of battery automatica...

Страница 11: ...on the right side of second line sets the voltage of the battery pack After setting the current and voltage press ENTER START button for more than 3 seconds to start the process Charge current 0 1 12...

Страница 12: ...10 at end of CV term The charging capacity may be a bit smaller than normal charging but the process time will be reduced This is for charging or discharging Lithium battery not to be used for the ti...

Страница 13: ...nnected to the individual port of the charger If the voltage of any one or more cells varies abnormally during discharge BC8HP terminates the process forcibly with the error message If this happens th...

Страница 14: ...mode to M or A using INC or DEC button Press ENTER START button to alter the charge current Change the current value using INC or DEC button Press ENTER START button for more than 3 seconds to start c...

Страница 15: ...r NiMH 2 0A 7 42V D C 022 45 00890 ENTER START TYPE STOP DEC INC DEC INC battery voltage discharge or charge current discharged or charged capacity elapsed time battery type 15 Display NiMH 0 REFLEX 3...

Страница 16: ...ranges from 0 1 to 12 0A and the voltage should be matched with the battery being charged ENTER the charge process by pressing ENTER START button for more than 3 seconds The screen displays the state...

Страница 17: ...sing the thermal probe The present voltage of input DC power Various information during the process DEC Display Capacity Cut Off ON 5000mAh Display Safety Timer ON 200min Display Temp Cut Off OFF 80C...

Страница 18: ...tive and monitoring the system to verify functions and the state of its electronics In any case of occurring error the screen displays the cause of error that is self explanatory with audible sound Th...

Страница 19: ...ry can deliver 60 amps of current for one hour 60Ax1hr 60Ah Nominal voltage V The nominal voltage of the battery pack can be determined as follows NiCd or NiMH multiply the total number of cells in th...

Страница 20: ...C159 Please read the instructions come with the board for the maximum safety Li Po 1S Li Po 2S Li Po 3S 4 cell 3 cell 2 cell 1 cell 5 cell 6 cell Individual bal port Li Po 1S Li Po 2S Li Po 3S BC8HP O...

Страница 21: ...m Warranty and service We warrant this product for a period of one year 12 months from the date of purchase The guarantee applies only to such material or operational defects which are present at the...

Отзывы: