Banner U-GAGE Q45U Скачать руководство пользователя страница 8

Q45U Long-Range Ultrasonic Sensors with Bipolar Discrete Outputs

P/N 48454 Rev. D

WARRANTY:

Banner Engineering Corp. warrants its products to be free from defects for one year. Banner Engineering Corp. will repair or

replace, free of charge, any product of its manufacture found to be defective at the time it is returned to the factory during the warranty period.
This warranty does not cover damage or liability for the improper application of Banner products. This warranty is in lieu of any other warranty
either expressed or implied.

Mounting Brackets

SMB30MM

•  30 mm, 11-gauge, stainless steel bracket with

curved mounting slots for versatility and orientation

•  Clearance for M6 (1/4") hardware

35.1 mm

(1.38")

35.1 mm

(1.38")

69.9 mm

(2.75")

7.1 mm
.28 x 90

°

 (2 Slots)

R 25.4 mm

(1.00")

ø30.1 mm

(1.19")

57.2 mm

(2.25")

25.4 mm

(1.00")

25.4 mm

(1.00")

ø 6.4 mm

(0.25" dia.)

57.2 mm

(2.25")

SMB30C

•  30 mm split clamp, black PBT bracket
•  Stainless steel mounting hardware included

SMB30S

•  30 mm swivel, black PBT bracket
•  Stainless steel mounting hardware included

56.0 mm

(2.20")

63.0 mm

(2.48")

45.0 mm

(1.77")

2.5 mm
(0.10")

31.5 mm

(1.24")

Nut Plate

M5 x 0.8
x 80 mm

Screw (2)

13 mm

(0.5")

13.5 mm (0.53")

63.5 mm

(2.50")

50.8 mm

(2.00")

M5 x 0.8
x 30 mm
Screw (2)

Not Shown:
(2) M5 x 0.8 x 60 mm
screws are supplied for
clamping bracket together

43.2 mm

(1.70")

25.4 mm

(1.00")

82.5 mm

(3.25")

12.2 mm

(0.48")

Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]

Содержание U-GAGE Q45U

Страница 1: ...tance for a 20 C change in temperature Temperature compensated models maintain the position of both sensing window limits to within 1 of each limit distance over the range of from 0 to 50 C and to wit...

Страница 2: ...ing the two slots shown in Figure 1 a small flat blade screwdriver may be used to lift up and remove the black inner cover to expose the 4 position DIP switch Figure 2 Those switches are used to progr...

Страница 3: ...nsor in a fill level application Sensor High Level Near Limit Pump in Application switch 1 off Pump out Application switch 1 on Low Level Far Limit Initial Level 1 Initial Tank Level Outputs are INACT...

Страница 4: ...ond limit 3 The programming sequence may be cancelled at any time by pressing and holding the push button for 2 seconds The sensor returns to RUN mode with the previously programmed limits 4 During li...

Страница 5: ...echo 5 segment moving dot LED indicates the position of the target within the sensing window Hysteresis ON OFF mode 10 mm HIGH LOW mode 0 mm Performance Specifications Repeatability 0 1 of measured d...

Страница 6: ...3500 mm 40 4000 mm 60 Q45U Effective Beam with 100 mm x 100 mm Plate Target Typical Q45U Series Dimensions 79 4 mm 3 13 44 5 mm 1 75 69 0 mm 2 72 87 6 mm 3 45 30 0 mm 1 18 Internal Thread 1 2 NPSM Ext...

Страница 7: ...Shield MQDEC2 506 MQDEC2 515 MQDEC2 530 2 m 6 5 5 m 15 9 m 30 Style Model Length Connector 5 Pin Mini style with Shield MBCC2 506 MBCC2 512 MBCC2 530 2 m 6 5 4 m 12 9 m 30 7 8 16UN 2B 28 mm 1 1 61 mm...

Страница 8: ...with curved mounting slots for versatility and orientation Clearance for M6 1 4 hardware 35 1 mm 1 38 35 1 mm 1 38 69 9 mm 2 75 7 1 mm 28 x 90 2 Slots R 25 4 mm 1 00 30 1 mm 1 19 57 2 mm 2 25 25 4 mm...

Отзывы: