Reading Parameters
35
Second Zone Trigger Level
This parameter allows setting the active state of the trigger. When the selected state is active, the oscillating mirror
starts working in the second reading zone according to the parameters set:
Selections:
Active Open
Active Closed
Second Zone Oscillating Mode
This parameter defines the oscillating mode of the scanner mirror to be used in the second reading zone:
Selections:
Fixed
the oscillating mirror deflects the scan line at a fixed Second Zone Angle
(default 10°).
Continuous
the scan line is deflected according to the Second Zone Min-Max Angle and
Second Zone Frequency settings.
Second Zone Angle (degrees)
This parameter is available only when the second reading zone is working in
Fixed Second Zone Oscillating Mode
.
It defines the angle in degrees with respect to the angle perpendicular to the scanner (0°).
The default value is 10°.
Selections: a value from
-5°
to
35°
:
Second Zone Min Angle (degrees)
This parameter is available only when the second reading zone is working in
Continuous Second Zone Oscillating
Mode
.
It defines the minimum angle for the second zone deflection range with respect to the angle perpendicular to the
scanner (0°).
Selections: a value from
-5°
to
35°
:
Second Zone Max Angle (degrees)
This parameter is available only when the second reading zone is working in
Continuous Second Zone Oscillating
Mode
.
It defines the maximum angle for the second zone deflection range with respect to the angle perpendicular to the
scanner (0°).
Selections: a value from
-5°
to
35°
:
Second Zone Frequency (Hz)
This parameter is available only when working in
Continuous Second Zone Oscillating Mode
.
It defines the oscillating frequency in Hertz for the second oscillating zone:
Selections: a value from
0.2
to
20.0
Hertz:
NOTE
The maximum allowable frequency for the given oscillating amplitudes is:
30.5° to 40° 5 Hz
20.5° to 30° 7 Hz
10.5° to 20° 10 Hz
0.5 to 10° 20 Hz