background image

Modbus Register Table (High Resolution Mode, DX99)

I/O

Modbus Holding Register

I/O Type

Units

I/O Range

Holding Register Val-
ue

Terminal

Block Labels

Gateway

Any Node

Min.

Max.

Min.
(Dec.)

Max.
(Dec.)

1

1

1 + (Node# × 16)

Discrete IN 1

-

0

1

0

1

DI1

2

2

2 + (Node# × 16)

Discrete IN 2

-

0

1

0

1

DI2

3

3

3 + (Node# × 16)

Thermocouple IN 1

°F/°C

-1638.3

+1638.4

0

65535

A1+/A1-

4

4

4 + (Node# × 16)

Thermocouple IN 2

°F/°C

-1638.3

+1638.4

0

65535

A2+/A2-

5

5

5 + (Node# × 16)

Thermocouple IN 3

°F/°C

-1638.3

+1638.4

0

65535

A3+/A3-

6

6

6 + (Node# × 16)

Thermistor IN

°F/°C

-1638.3

+1638.4

0

65535

A4+/A4-

7

7

7 + (Node# × 16)

Reserved

8

8

8 + (Node# × 16)

Device Message

...

15

15

15 + (Node# × 16)

Control Message

16

16

16 + (Node# × 16)

Reserved

In high resolution mode, the temperature = (Modbus register value) ÷ 20. In low resolution mode, the temperature is (Modbus register
value) ÷ 2.
Temperature values are stored as signed values in the Modbus register. A 0 in the register is interpreted as 0°; and 65535 in the register
(0xFFFF) is interpreted as −1 ÷ 20 = −0.05° in high resolution mode and –1 ÷ 2 = –0.5° in low resolution mode.

Storage Mode and Sleep Mode

While in storage mode, the radio does not operate. All SureCross

®

 radios powered from an integrated battery ship from the factory in

storage mode to conserve the battery. To wake the device, press and hold button 1 for five seconds. To put any FlexPower

®

 or integra-

ted battery SureCross radio into storage mode, press and hold button 1 for five seconds. The radio is in storage mode when the LEDs
stop blinking, but in some models, the LCD remains on for an additional minute after the radio enters storage mode. After a device has
entered storage mode, you must wait one minute before waking it.
During normal operation, the SureCross radio devices enter sleep mode after 15 minutes of operation. The radio continues to function,
but the LCD goes blank. To wake the device, press any button.

Specifications

Radio

General

Range

900 MHz: Up to 4.8 kilometers (3 miles)
2.4 GHz: Up to 3.2 kilometers (2 miles)

Transmit Power

900 MHz: 21 dBm (150 mW) conducted
2.4 GHz: 18 dBm (65 mW) conducted, less than or equal to
20 dBm (100 mW) EIRP

900 MHz Compliance (150 mW Radios)

FCC ID TGUDX80 - This device complies with FCC Part 15,
Subpart C, 15.247
IC: 7044A-DX8009

Power

Requirements: 3.6V dc low power option (from the DX81H
Battery Supply Module)
Consumption: Application dependant

Housing

Polycarbonate housing and rotary dial cover; polyester la-
bels; EDPM rubber cover gasket; nitrile rubber, non-sulphur
cured button covers
Weight: 0.26 kg (0.57 lbs)
Mounting: #10 or M5 (SS M5 hardware included)
Max. Tightening Torque: 0.56 N·m (5 lbf·in)

Antenna Connection

Ext. Reverse Polarity SMA, 50 Ohms
Max Tightening Torque: 0.45 N·m (4 lbf·in)

SureCross DX99 FlexPower Thermocouple Node (Polycarbonate Housing)

 

 

P/N 142498 Rev. E

www.bannerengineering.com - tel: 763-544-3164

5

Содержание SureCross FlexPower DX99 Series

Страница 1: ...de the Canadian Electrical Code or applicable local codes regulations Model Frequency I O DX99N9X2S2N0T4X0A0 900 MHz ISM Band Inputs Two selectable discrete three thermocouple one thermistor for CJC DX99N2X2S2N0T4X0A0 2 4 GHz ISM Band Internal antenna models are also available For more information contact your local Banner Engineering Corp representative WARNING Not To Be Used for Personnel Protec...

Страница 2: ...ot be recognized if power isn t cycled to the device Accessing the Internal DIP Switches To access the internal DIP switches follow these steps 1 Unscrew the four screws that mount the cover to the bottom housing 2 Remove the cover from the housing without damaging the ribbon cable or the pins the cable plugs into 3 Gently unplug the ribbon cable from the board mounted into the bottom housing 4 Re...

Страница 3: ...on To use extended address mode change the DIP switch to the ON position Discrete Input Type Select the type of discrete input sensors to use with this device sourcing PNP sensors or sinking NPN sensors Modbus User Configuration Tool UCT or DIP Switch Configured In Modbus UCT Configured mode the device parameters are changed using the User Configuration Tool UCT or a Modbus command All DIP switch ...

Страница 4: ...I1 GND Ax and Ax Analog IN x Analog inputs for devi ces requiring more than one connection such as thermocouples or RTDs When there is no Ax use Ax as an analog input DIx Discrete IN x GND Ground dc common connection 1 2 3 4 5 FlexPower 3 blue dc common GND 5 gray 3 6V dc Only use the DX81H Bat tery Supply Module to power this device LED Behavior for the Nodes After powering up and binding the Gat...

Страница 5: ...exPower or integra ted battery SureCross radio into storage mode press and hold button 1 for five seconds The radio is in storage mode when the LEDs stop blinking but in some models the LCD remains on for an additional minute after the radio enters storage mode After a device has entered storage mode you must wait one minute before waking it During normal operation the SureCross radio devices ente...

Страница 6: ...95 max relative non condensing Radiated Immunity 10 V m 80 2700 MHz EN61000 6 2 Shock and Vibration IEC 68 2 6 and IEC 68 2 7 Shock 30g 11 millisecond half sine wave 18 shocks Vibration 0 5 mm p p 10 to 60 Hz Refer to the SureCross DX80 Wireless I O Network Product Manual p n 132607 for installation and waterproofing instructions Operating the devi ces at the maximum operating conditions for exten...

Страница 7: ...ries using the antenna that ships with the product When using other antennas verify you are not exceeding the transmit power levels allowed by local governing agencies Consult with Banner Engineering Corp if the destination country is not on this list Violating Warnings The manufacturer does not take responsibility for the violation of any warning listed in this document Make no modifications to t...

Страница 8: ... STRICT LIABILITY NEGLIGENCE OR OTHERWISE Banner Engineering Corp reserves the right to change modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp SureCross DX99 FlexPower Thermocouple Node Polycarbonate Housing www bannerengineering com tel 763 544 3164 ...

Отзывы:

Похожие инструкции для SureCross FlexPower DX99 Series