background image

DR*M-H1

DR*M-H1C

DR*M-H1E

SP4

AX2
AX1

GND
DI4

GND
DO2

DI2

SP3

AI3
AI1

GND
DI3

GND
DO1

DI1

G B − W +

TX/+

RX/

BAT

GND

PWR

GND

AX2

SP4

SP3

AI3

AX1

DI4

DO2

DI2

DI1

DO1

DI3

AI1

+

A3

A4

A1

A2

-

AX2

SP4 SP3

AI3

AX1

GND

SP2

GND

DO2

DI2 DI1

DO1

GND

SP1

GND

AI1

AIx or Ax. Analog IN x.

AOx. Analog OUT x.

AX1. Counter IN.

AX2. Thermistor IN.

DIx. Discrete IN x.

DOx. Discrete OUT x.

B+. 3.6 to 5.5 V dc (for battery powered

models only).

RX/-. Serial comms line for Gateways and

DX85s only. No connection for Nodes.

TX/+. Serial comms line for Gateways and

DX85s only. No connection for Nodes

GND. Ground/dc common

connection.

PWR. Power, 10 to 30 V dc power

connection.

SPx. Switch Power. Provides

variable power sources for external

devices.

Discrete Input Wiring for PNP

Sensors

Discrete Input Wiring for NPN

Sensors

Discrete Output Wiring (NPN or

NMOS)

Discrete IN

PWR

10-30V dc

Discrete IN

GND

dc common

Load

Discrete OUT

GND

PWR

10-30V dc

dc common

Analog Input Wiring (10 to 30 V dc

Power)

Analog Input Wiring (4 to 20mA, 2-

Wire, Externally-Powered Sensors)

Analog Input Wiring (4 to 20mA, 2-

Wire, Switch-Powered Sensors)

Analog IN

PWR

10-30V dc

GND

+

sensor

dc common

Analog IN

GND

dc common

external power

+

sensor

+

Analog IN

SPx

GND

+

sensor

dc common

(Only possible in models with switch

power (SPx) outputs)

 

 

SureCross MultiHop Data Radio

6

www.bannerengineering.com - tel: 763-544-3164

P/N 148947 Rev. C

Содержание SureCross DX80DR2M-H1

Страница 1: ...y module IP67 NEMA 6 Inputs Four sinking discrete two 0 to 20 mA analog one thermistor one sinking counter Outputs Two NMOS discrete two switch power Serial interface RS 485 DX80DR9M H1E 10 to 30 V dc...

Страница 2: ...op Master Radio Within a network of MultiHop data radios there is only one master radio The master radio controls the overall timing of the network and is always the parent device for other MultiHop r...

Страница 3: ...duct Manual 151317 MultiHop Register Guide End User Edition 155289 Configure the DIP Switches Before making any changes to the DIP switch positions disconnect the power DIP switch changes will not be...

Страница 4: ...ible to enable broadcast acknowledgement of the data packets to provide better throughput In transparent mode there is no access to the radio s I O Baud Rate and Parity The baud rate bits per second i...

Страница 5: ...dc 10 to 30 V dc Tx RS 485 D1 B RS 485 D1 B V dc common GND dc common GND Rx RS 485 D0 A RS 485 D0 A B 3 6 to 5 5 V dc Wiring for DX80 E Radios Connecting dc power to the communication pins will cause...

Страница 6: ...connection PWR Power 10 to 30 V dc power connection SPx Switch Power Provides variable power sources for external devices Discrete Input Wiring for PNP Sensors Discrete Input Wiring for NPN Sensors D...

Страница 7: ...60 Modbus Register Maps Register 4xxxx Input Input Type Units I O Range Holding Register Representation Terminal Block Labels Min Value Max Value Min Dec Max Dec 1 1 Discrete IN 1 0 1 0 1 DI1 2 2 Dis...

Страница 8: ...ut 2 output 1 etc Operation type specific parameters discrete counter analog 4 to 20 mA are grouped together based on the I O type number analog 1 analog 2 counter 1 etc Not all inputs or outputs may...

Страница 9: ...Remove the four screws mounting the face plate to the housing and remove the face plate Do not remove the radio cover from the face plate 2 Remove the discharged battery and replace with a new battery...

Страница 10: ...on covers Weight 0 26 kg 0 57 lbs M Hx and M HxC models Mounting 10 or M5 SS M5 hardware included M HxE models Mounting 1 4 inch or M7 SS M7 hardware included Max Tightening Torque 0 56 N m 5 lbf in I...

Страница 11: ...BWA 9O2 C 900 MHz or BWA 2O2 C 2 4 GHz Antenna 2 dBd Omni Rubber Swivel RP SMA Male Not included with Internal antenna models Quick Start Guide 128185 for DX80 Gateways or 152653 for MultiHop models...

Страница 12: ...ted Warranty Banner Engineering Corp warrants its products to be free from defects in material and workmanship for one year following the date of shipment Banner Engineering Corp will repair or replac...

Отзывы: