Banner Engineering Corp. Limited Warranty

Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge,

any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the

improper application or installation of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR

FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER

PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR

FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner

Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such

purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this

document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is

provided in any other language. For the most recent version of any documentation, refer to: 

www.bannerengineering.com

.

For patent information, see 

www.bannerengineering.com/patents

.

 

 

Sure Cross

®

 MultiHop H3E-NB-KR Data Radio

 

©

 Banner Engineering Corp. All rights reserved

 

Содержание Sure Cross MultiHop H3E-NB-KR

Страница 1: ...ergized off output condition Important Electrostatic discharge ESD sensitive device ESD can damage the device Damage from inappropriate handling is not covered by warranty Use proper handling procedures to prevent ESD damage Proper handling procedures include leaving devices in their anti static packaging until ready for use wearing anti static wrist straps and assembling units on a grounded stati...

Страница 2: ...and enable the receiver slots select for switches 1 2 ON ON Transmit power 900 MHz radios 1 00 Watt 30 dBm 2 4 GHz radios 0 065 Watts 18 dBm and 60 ms frame OFF Transmit power 900 MHz radios 0 25 Watts 24 dBm 2 4 GHz radios 0 065 Watts 18 dBm and 40 ms frame ON Application mode Modbus OFF Application mode Transparent ON MultiHop radio setting Repeater OFF OFF MultiHop radio setting Master OFF ON M...

Страница 3: ...nected to the BAT terminal When powering the device from the integrated battery the BAT connection must remain open Integrated battery RS 485 for P1E M H1E M H12E and P16E Models Integrated battery RS 232 for P3E P4E M H3E and M H4E Models 1 2 3 4 BAT 1 10 V dc to 30 V dc optional 10 V dc to 30 V dc optional 2 RS 485 D1 B RS 232 Tx 3 dc common GND dc common GND 4 RS 485 D0 A RS 232 Rx Terminal Blo...

Страница 4: ...an RS 485 to USB adapter cable with a wall plug that can power your 1 Watt MultiHop radio while you configure it The adapter cable is not required when connecting to a DXM Controller Download the most recent software revision from the Wireless Reference Library on Banner Engineering s website www bannerengineering com Installing Your Sure Cross Radios Please refer to one of the following instructi...

Страница 5: ...t configuration is set to a Type B thermocouple 0 Value Thermocouple Type Value Thermocouple Type Value Thermocouple Type 0 B 5 J 10 P 1 C 6 K 11 R 2 D 7 L 12 S 3 E 8 M 13 T 4 G 9 N 14 U Modbus Addressing Convention All Modbus addresses refer to Modbus holding registers When writing your own Modbus scripts use the appropriate commands for interfacing to holding registers Parameter description head...

Страница 6: ...s these are a fire explosion and severe burn hazard Do not burn or expose them to high temperatures Do not recharge crush disassemble or expose the contents to water For hazardous or non hazardous locations the replacement battery model number is BWA BATT 001 Xeno model number XL 205F For non hazardous locations only the replacement battery model number is BWA BATT 011 For pricing and availability...

Страница 7: ...ckel finish PVC insulation 3 2 35 mm 6 mm 4 20 mm 72 mm Tube Included with the DX80 E Models Mounting hardware kit BWA HW 003 PTFE tape BWA 9O2 C 900 MHz or BWA 2O2 C 2 4 GHz Antenna 2 dBd Omni Rubber Swivel RP SMA Male Not included with Internal antenna models BWA BATT 001 Replacement battery 3 6 Volt D Lithium Cell BWA HW 032 Access Hardware for E Housing One each of 1 2 inch plug 1 2 inch gland...

Страница 8: ...NTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT WHETHER ARISING IN CONTRACT OR WARRANTY STATUTE TORT STRICT LIABILITY NEGLIGENCE OR OTHERWISE Banner Engineering Corp reserves the right to change modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Ban...