Rated Operating Voltage (Ue) and Current
Safety Contact (N.C.)
30 V
125 V
250 V
AC 50/60 Hz
Resistive Load (AC-12)
-
5 A
3 A
Inductive Load (AC-15)
-
3 A
1.5 A
DC
Resistive Load (DC-12)
2 A
0.4 A
0.2 A
Inductive Load (DC-13)
1 A
0.22 A
0.1 A
Monitor Contacts (N.O.)
30 V
125 V
250 V
AC 50/60 Hz
Resistive Load (AC-12)
-
1.2 A
0.6 A
Inductive Load (AC-14)
-
0.6 A
0.3 A
DC
Resistive Load (DC-12)
2 A
0.4 A
0.2 A
Inductive Load (DC-13)
1 A
0.22 A
0.1 A
The operating current is classified according to EN 60947-5-1 making and breaking capacities and are measured at resistive/inductive load types specified in
EN 60947-5-1. See "Electrical Rating" above for specific model and UL/CE maximum ratings.
Required Overcurrent Protection
WARNING:
Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and
regulations.
Overcurrent protection is required to be provided by end product application per the supplied table.
Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go to www.bannerengineering.com.
Supply Wiring (AWG)
Required Overcurrent Protection (Amps)
20
5.0
22
3.0
24
2.0
26
1.0
28
0.8
30
0.5
Dimensions
SSA-EB Series Emergency Stop Push Button
8
www.bannerengineering.com - Tel: + 1 888 373 6767
P/N 194992 Rev. D