background image

Instruction Manual

30 mm Panel Mount Electro-Mechanical Push Buttons

Four styles of actuators: standard, illuminated, lockable, and illuminated lockable

Push-to-stop, twist-to-release (standard and lockable), or pull-to-release (standard)

operation per IEC 60947-5-5

Latching design complies with ISO 13850; direct (positive) opening operation per EN

60947-5-1

Compliant with ANSI B11.19, NFPA 79, and IEC/EN 60204-1 Emergency Stop

requirements

“Safe Break Action” ensures normally closed (NC) contacts will open if the contact block

is separated from the actuator

Panel mount though 30 mm mounting hole

"Emergency Stop" legend optional

Models SSA-EB… series are "mushroom-style" electro-mechanical emergency stop push buttons. These buttons mount through a

30 mm hole in an enclosure. When the button is armed, the switch's safety contacts (normally closed/NC) are closed and its

monitoring contacts (normally open/NO), if present, are open. When the button is pushed, the switch's safety contacts open, and the

monitoring contacts close. The contacts remain in this condition until they are manual rearmed.
The standard 40 mm and 60 mm actuators can be rearmed by pulling or twisting clockwise the red actuator. The lockable 44 mm

actuator can be rearmed only by twisting the actuator clockwise. Do not pull the actuator while twisting or the switch may be

damaged, causing a malfunction or operational failure. The illuminated models provide a red indication within the face of the button

that allows for easy identification of a pushed/actuated button.
SSA-EB1M… series padlock-style lockable emergency stop push buttons are intended to prevent unauthorized or accidental

resetting of a pushed/latched button. The SSA-EB1M… series are not to be used as an energy isolating device or as the sole means

of complying with Lockout/Tagout or with the requirements of the isolation of hazardous energy (see OSHA 29CFR1910.147, ANSI

Z244.1, CSA Z460, ISO 14118). The locking feature can be used to provide supervisory/personal control and provide an additional

safety measure(s) to reduce the likelihood of inadvertent arming and energization of the emergency stop circuit.

Models

Table 1: Non-illuminated models

Standard 40 mm

Standard 60 mm

Lockable 44 mm

Safety Contacts

Monitor Contacts

SSA-EB1P-02

SSA-EB2P-02

SSA-EB1MP-02

2 normally closed (NC)

SSA-EB1P-04

SSA-EB2P-04

SSA-EB1MP-04

4 normally closed (NC)

SSA-EB1P-11

SSA-EB2P-11

SSA-EB1MP-11

1 normally closed (NC)

1 normally open (NO)

SSA-EB1P-13

SSA-EB2P-13

SSA-EB1MP-13

3 normally closed (NC)

1 normally open (NO)

SSA-EB1P-22

SSA-EB2P-22

SSA-EB1MP-22

2 normally closed (NC)

2 normally open (NO)

Table 2: Illuminated models

Standard 40 mm

Lockable 44 mm

LED

Safety Contacts

Monitor Contacts

SSA-EB1PL1-02

SSA-EB1ML1P-02

Per wiring connection

2 normally closed (NC)

SSA-EB1PL1-04

SSA-EB1ML1P-04

Per wiring connection

4 normally closed (NC)

SSA-EB1PL1-11

SSA-EB1ML1P-11

Per wiring connection

1 normally closed (NC)

1 normally open (NO)

SSA-EB1PL1-13

SSA-EB1ML1P-13

Per wiring connection

3 normally closed (NC)

1 normally open (NO)

SSA-EB1PL1-22

SSA-EB1ML1P-22

Per wiring connection

2 normally closed (NC)

2 normally open (NO)

SSA-EB1PL2-12

SSA-EB1ML2P-12

PUSH ON

2 normally closed (NC)

1 normally open (NO)

ISD Connect—All models with 2 normally closed (NC) contacts can be used with Banner's 

SSA-ISD-TCA

 by using an

MQDMC-5xx(RA)

 series cable.

Important... Read this before proceeding!

The user is responsible for satisfying all local, state, and national laws,

 rules, codes, and regulations relating to the use of this

product and its application. Banner Engineering Corp. has made every effort to provide complete application, installation, operation,

and maintenance instructions. Please contact a Banner Applications Engineer with any questions regarding this product.

SSA-EB Series Emergency Stop Push Button

 

 

Original Document

194992 Rev. D

21 September 2022

194992

Содержание SSA-EB Series

Страница 1: ...quirements of the isolation of hazardous energy see OSHA 29CFR1910 147 ANSI Z244 1 CSA Z460 ISO 14118 The locking feature can be used to provide supervisory personal control and provide an additional...

Страница 2: ...es WARNING Connect two or more devices to the same safety module controller in series Connecting devices in parallel defeats the switch contact monitoring ability of the module and creates an unsafe c...

Страница 3: ...hten the M30 jam nut using wrench SSA EB1 LRW or SSA EB1 LRTW to a maximum torque of 2 5 N m 1 8 ft lbs Note The allowable panel thickness is 1 mm to 5 mm for SSA EB1P and 1 mm to 6 mm for SSA EB1M Ba...

Страница 4: ...PL1 11 SSA EB1ML1P 11 1 normally closed NC 1 normally open NO 11 12 X2 23 24 X1 LED24V SSA EB1P 13 SSA EB1MP 13 3 normally closed NC 1 normally open NO 22 11 12 21 41 42 34 33 SSA EB1PL1 13 SSA EB1ML1...

Страница 5: ...Cover Install the SSA EB1 TC Terminal Cover 1 Align the TOP mark on the SSA EB1 TC terminal cover with the TOP mark on the contact block 2 Place the two projections on the bottom of the contact block...

Страница 6: ...hould test each safety point for proper machine shutdown response A Designated Person should check the safety point for proper operation physical damage button looseness and excessive environmental co...

Страница 7: ...mA Output Configuration See Installation and Maintenance on page 2 Mechanical Life 250 000 operations Terminals M3 screw terminal terminal cover included Recommended Torque 0 6 to 1 0 N m 5 3 to 8 8 i...

Страница 8: ...0947 5 1 See Electrical Rating above for specific model and UL CE maximum ratings Required Overcurrent Protection WARNING Electrical connections must be made by qualified personnel in accordance with...

Страница 9: ...rol units of different sizes and styles determine the values according to the dimensions operation and wiring convenience For padlock style lockable emergency stop push buttons determine the values ac...

Страница 10: ...d contact blocks including LED indicators are only available as complete units and are not sold separately SSA EB1 FSTC IP20 Finger safe terminal cover SSA EB1 TC Standard terminal cover supplied SSA...

Страница 11: ...Assessment and Risk Reduction ISO 13850 EN 418 Emergency Stop Devices Functional Aspects Principles for Design IEC 62061 Functional Safety of Safety Related Electrical Electronic and Programmable Cont...

Страница 12: ...RA COSTS EXPENSES LOSSES LOSS OF PROFITS OR ANY INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT WHETHER ARISING IN CONTRAC...

Отзывы: