3.8.6.  Wire the Switch in Series Using the Quick Disconnect

Use models 

SI-RFS

 and 

SI-RFD

 for this configuration.

C

ONTEXT

:

When connecting units in series, simplify the wiring using special t-adapters and low-cost unshielded four-wire double-ended cables. A similar 

configuration is shown except the connections are all made using quick disconnects. The 

SSA-EB1PLx-0Dx

 E-stops, 

SI-RFD

 switches, and the 

SSA-ISD Connect can be combined in a single chain.

1.

Connect the female 4-pin M12 cable to the male 4-pin M12 of the series connection t-adapter (

SI-RFA-TS

).

2.

If a manual reset model sensor is used, connect the female 8-pin M12 of the Reset T-Adapter (

SI-RFA-TK

) to the male 8-pin M12 

connector of the series connection t-adapter. Connect a female 4-pin M12 cable to the male 4-pin M12 QD of the t-adapter for 

connecting a reset switch or reading the Auxiliary output.

3.

Connect the sensor to the male 8-pin M12 connector of the t-adapter.

4.

Connect the male 4-pin M12 end of a double-ended cable to the female 4-pin M12 of the t-adapter. Connect the female 4-pin M12 end 

of the double-ended cable to the next series connection t-adapter (

SI-RFA-TS

).

5.

At the end of the line a terminating plug (

SI-RFA-P

) is required to properly truncate the system.

6.

The wired end of the 4-pin M12 cable (from step 1) can be wired directly to a Safety Monitoring Module or can be wired through an 

In-Series Diagnostic (ISD) module then to the Safety Monitoring device.

A

FTER

 C

OMPLETING

 T

HIS

 T

ASK

:

Verify that the SI-RF Safety Switch and the safety monitoring module are powered from the same power supply or the commons of the separate 

supplies are the same. Ensure that the voltage level at SI-RF 1 (furthest from the power supply) is above 19.5 V for the system to operate prop

-

erly.

Figure 7: 

Wiring the switch in series using the quick disconnect connector

In long chains, or chains with a lot of ISD devices, the voltage at the first device (device closest to terminating plug) must stay above 19.5 V for 

the chain to operate properly.
For guidance on the maximum total cable length and a maximum number of devices before an additional power supply may be needed, refer to 

Maximum total cable length for a single power supply

. For using ISD information to monitor the individual device voltages, see 

In-Series Diag

-

nostic Information on page 8

.

An additional power supply may be required to maintain a minimum of 19.5 V at all devices. There are two options to connect an additional power 

supply.

SI-RFA-TS

4-pin male connection

SI-RFA-TK

SI-RFA-P Termination

MQDEC-4xxSS (4 lengths)

MQDC-4xx (4 lengths)

Bk

PNP Aux Output
NOT FOR SAFETY

ONLY FOR DOOR 4

Power

Safety 

Monitoring 

Module

24Vdc 0Vdc

OSSDs

Bn

Bu

Wh

Bk

Bn

Wh

Reset

1

2

3

4

Component Key

8-pin female connection

SI-RFA-TS

SI-RFA-P

SI-RFA-TK

SI-RFA-TS

SI-RFA-TS

SI-RFA-TS

MQDC-4xx

SI-RFA-TK

MQDEC-4xxSS

MQDEC-4xxSS

MQDEC-4xxSS

MQDC-4xx

MQDC-4xx

24Vdc

0Vdc

DEE2R-8xxD

Содержание SI-RFST-UP8

Страница 1: ...SI RF Non Contact RF Safety Switch Instruction Manual February 27 2023 Banner Engineering Corp All rights reserved...

Страница 2: ...al Installation 9 Protective Stop Safety Stop Circuits 9 Output Signal Switching Devices OSSDs and External Device Monitoring EDM 9 Fault Tolerant Output Feature 10 Wiring for Single PNP SI RFP 10 Wir...

Страница 3: ...f this product must be thoroughly familiar with all applicable standards some of which are listed within the specifications Banner Engineering Corp makes no claim regarding a specific recommendation o...

Страница 4: ...pplications unless another means of locking is provided The SI RF Safety Switch is considered a Type 4 interlocking device per ISO 14119 that are actuated by an electronic field interacting with the c...

Страница 5: ...of the SI RF Safety Switch 2 Energize the SI RF Safety Switch for minimum 5 seconds STEP RESULT The amber and green LED on the SI RF Safety Switch flash with flash code 6 for 1 5 seconds see Status In...

Страница 6: ...ion The switches actuating systems and actuators must not be used as a mechanical or end of travel stop When the guard is closed the actuator is guided to the sensor When the switch on distance is rea...

Страница 7: ...unobstructed view of the entire guarded area while the reset is performed Out of reach from within the guarded area Protected against unauthorized or inadvertent operation such as through the use of r...

Страница 8: ...manipulated by an operator to defeat the safety function s for example cannot remove a switch from the chain 3 4 Sensing Distance Figure 1 Actuation directions The switching distances of the standard...

Страница 9: ...ee operation IMPORTANT If two actuators are used to activate one sensor the actuators must have a separation distance of at least 20 mm measured from the side of the housings Figure 3 Sensor and actua...

Страница 10: ...e 3 6 Auxiliary Output Information The PNP output models SI RFS and SI RFP have a diagnostic PNP output The PNP Diagnostic is not safety related The PNP Diagnostic output indicates whether the right a...

Страница 11: ...he loss of the safety function Such a circuit can be described as a safe switching point Typically protective stop circuits are either single channel which is a series connection of at least two norma...

Страница 12: ...used with an external safety monitoring device that monitors the status of the two SI RF Safety Switch OSSDs and is capable of providing the EDM function Examples of appropriate external safety monit...

Страница 13: ...Auxillary PNP output Do The following table describes the wiring of the different model options 5 Gray PNP OUT Auxillary Output PNP OUT Auxillary Output Pin SXA 8xxD Wire Color Pin Wire Function SI R...

Страница 14: ...te the diagnostic device between the last SI RF Safety Switch and the safety monitoring module in the series connection The status information can then be retrieved from the diag nostic device AFTER C...

Страница 15: ...irectly to a Safety Monitoring Module or can be wired through an In Series Diagnostic ISD module then to the Safety Monitoring device AFTER COMPLETING THIS TASK Verify that the SI RF Safety Switch and...

Страница 16: ...ces the current draw of the emergency stop devices governs the cable lengths and when more power is needed The maximum cable length between devices including the last unit and the ISD evaluation devic...

Страница 17: ...S WARNING SAFETY DEVICES WITH OSSDS AND WITHOUT ISD SUCH AS SAFETY LIGHT CURTAINS ARE NOT COMPATIBLE Failure to follow these instructions could result in serious injury or death Do not use safety devi...

Страница 18: ...rent I0 50 mA Transponder frequency 125 kHz Switching frequency 1 Hz Switch off delay ta 100 ms maximum 7 ms number of following ISD devices Time delay tv Maximum 2 s Rated impulse withstand voltage U...

Страница 19: ...8 SI RFDT LP8 SI RFDT UP8 SI RFPT H2M SI RFPT L2M SI RFPT U2M 4 1 Dimensions All measurements are listed in millimeters unless noted otherwise Figure 1 SI RF Safety Switch Sensor Figure 2 SI RF Safety...

Страница 20: ...506 2 m 6 5 ft MQDC1 515 5 m 16 4 ft MQDC1 530 9 m 29 5 ft MQDC1 560 18 m 59 ft MQDC1 5100 31 m 101 7 ft MQDC1 506RA 2 m 6 5 ft Right Angle MQDC1 515RA 5 m 16 4 ft MQDC1 530RA 9 m 29 5 ft MQDC1 560RA...

Страница 21: ...9 m 2 9 ft Male Right Angle Female Right Angle MQDEC 406RR 1 8 m 5 9 ft MQDEC 412RR 3 6 m 11 8 ft MQDEC 420RR 6 1 m 20 ft 8 Pin Threaded M12 Cordsets Double Ended Model 8 pin 8 pin Length Style Dimens...

Страница 22: ...1 SI RF Diagnostic Module with 8 digital outputs and 1 diagnostic circuit Interfaces IO Link USB 2 0 SI RDA DM2 SI RF Diagnostic Module with 1 diagnostic circuit IP69 rated Interfaces IO Link CSB M125...

Страница 23: ...vailable via ISD The following information can be obtained from the ISD chain and a diagnostic unit or ISD enabled Safety Controller Cyclic data about the chain that can be obtained from an ISD enable...

Страница 24: ...sensor not taught an actuator ISD Fault 1 bit An SI RF switch UP8 or HP8 have not been taught Configure the unit to its actuator per instruc tions in Banner datasheet p n 208885 Wrong actuator presen...

Страница 25: ...r SI RF models with ISD Fault Tolerant Outputs 1 0 Indicates that the ISD Device includes the fault tolerant output feature where output faults cause a 20 minute off delay fault delay NOTE This will a...

Страница 26: ...AL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT WHETHER ARISING IN CONTRACT OR WARRANTY STATUTE TORT STRICT LIABILITY NEGLIGENCE OR OTHERWISE Ba...

Страница 27: ...Banner Engineering Corp www bannerengineering com 25 PRODUCT SUPPORT AND MAINTENANCE...

Отзывы: