Banner SI-HG63 Series Скачать руководство пользователя страница 2

Figure 1. Contact Configuration (Gate Closed

State) for Quick Disconnect Models

33

21

11

rd/bu

gn

rd

34

22

12

rd/bk

rd/ye

rd/wh

Figure 2. Contact Configuration (Gate Open

State) for Quick Disconnect Models

33

21

11

rd/bu

gn

rd

34

22

12

rd/bk

rd/ye

rd/wh

Figure 3. Switching Diagram

1.5 Nm

Set Point

1.5 Nm

11-12

21-22

33-34

Safety

Safety

Non-Safety

Contacts:   Open   Closed   Transition

Figure 4. Contact Configuration (Gate Closed

State) for Cabled Models

pk

bn

gy

ye

wh

33

21

11

gn

34

22

12

Figure 5. Contact Configuration (Gate Open

State) for Cabled Models

pk

bn

gy

ye

wh

33

21

11

gn

34

22

12

Terminals 33 and 34 are non-safety.

Note: 

This symbol 

 for a positive-opening safety contact (IEC 60947-5-1) is used in the switching diagram to

identify the point in actuator travel where the normally-closed safety contact is fully open.

Important... Read this before proceeding!

The user is responsible for satisfying all local, state, and national laws,

 rules, codes, and regulations relating to the use of this

product and its application. Banner Engineering Corp. has made every effort to provide complete application, installation, operation,

and maintenance instructions. Please contact a Banner Applications Engineer with any questions regarding this product.

The user is responsible

 for making sure that all machine operators, maintenance personnel, electricians, and supervisors are

thoroughly familiar with and understand all instructions regarding the installation, maintenance, and use of this product, and with the

machinery it controls. The user and any personnel involved with the installation and use of this product must be thoroughly familiar

with all applicable standards, some of which are listed within the specifications. Banner Engineering Corp. makes no claim regarding

a specific recommendation of any organization, the accuracy or effectiveness of any information provided, or the appropriateness of

the provided information for a specific application.

Overview

Use the SI-HG(Z)63 Hinge Wing Safety Interlock Switch to monitor the position of a guard to detect the movement, opening, or

removal. A "guard" can be a gate, door, cover, panel, barrier or other physical means that separates an individual from a hazard.

The SI-HG(Z)63 will issue a signal to the machine control system to prevent or stop (halt) hazardous situations when the guard is not

in the proper position. The SI-HG(Z)63 is designed for non-locking guarding applications, unless another means of locking is

provided.

Installation Requirements

The following general requirements and considerations apply to the installation of interlocked gates and guards for the purpose of

safeguarding. In addition, the user must refer to the relevant regulations and comply with all necessary requirements. See ANSI

B11.19, or ISO 14119 and ISO 14120, or the appropriate standard.
Hazards guarded by the interlocked guard must be prevented from operating until the guard is closed; a stop command must be

issued to the guarded machine if the guard opens while the hazard is present. Closing the guard must not, by itself, initiate

hazardous motion; a separate procedure must be required to initiate the motion. The safety switches must not be used as a

mechanical or end-of-travel stop.
Locate the guard an adequate distance from the danger zone (so the hazard has time to stop before the guard is opened sufficiently

to provide access to the hazard). The guard must open either laterally or away from the hazard, not into the safeguarded area. The

guard also should not be able to close by itself and activate the interlocking circuitry. The installation must prevent personnel from

reaching over, under, around or through the guard to access the hazard. Any openings in the guard must not allow access to the

hazard—see ANSI B11.19, ISO 13857, or the appropriate standard. The guard must be strong enough and designed to protect

personnel and contain hazards within the guarded area that can be ejected, dropped, or emitted by the machine.
Design and install the safety interlocking switches and actuators so that they cannot be easily defeated. Mount them securely so that

their physical position cannot shift, using reliable fasteners that require a tool to remove. Mounting slots in the housing, if provided,

are for initial adjustment only; final mounting holes (round) must be used for permanent location.

 

 

SI-HG(Z)63 Hinge Wing Safety Interlock Switch

2

www.bannerengineering.com - Tel: + 1 888 373 6767

P/N 129465 Rev. G

Содержание SI-HG63 Series

Страница 1: ...nless Steel Inline QD With QD facing down switch is mounted on left side of hinge SI HGZ63FQDL Zinc Die cast SI HG63F5ML W Stainless Steel Inline Cable With cable exiting down switch is mounted on lef...

Страница 2: ...ver panel barrier or other physical means that separates an individual from a hazard The SI HG Z 63 will issue a signal to the machine control system to prevent or stop halt hazardous situations when...

Страница 3: ...se requirements Pass through hazards and Perimeter Guarding A pass through hazard is associated with applications where personnel may pass through a safeguard which issues a stop command to remove the...

Страница 4: ...nd that the guard or gate swings freely throughout its range of motion without binding If binding is noticed repeat the Mechanical Installation on page 3 2 Place the guard in its closed and latched po...

Страница 5: ...in a new location for example Changing the setting requires replacement of the red plastic washer See Replacement Accessory Kit on page 13 for a kit that includes a replacement washer The hinge must...

Страница 6: ...nto the enclosure until the switch cylinder arrow aligns with mark B on the switch housing The switch element should sink into the enclosure during this process Figure 16 Align to B 7 Press the switch...

Страница 7: ...codes such as the NEC National Electrical Code NFPA 79 or IEC 60204 1 and all applicable local standards and codes Connection to a Machine Electrical connection is via a 6 pin dual key M12 micro styl...

Страница 8: ...reliability OSHA 29CFR1910 or ANSI B11 19 or Category 3 or 4 ISO 13849 1 This is required to provide monitoring for safety switch failure and to provide the necessary reset routine as required by NFP...

Страница 9: ...r minute Switching Angle NC Contact 3 Positive opening 6 wear can cause increase by 2 NO Contact 9 Tolerance for all angles 1 5 Mechanical Load SI HG63 FR1 1800 N max FR2 750 N max FA 1800 N max SI HG...

Страница 10: ...mm 1 30 18 mm 0 71 4 0 mm 0 16 19 5 mm 0 77 Figure 23 Model SI HG Z 63F5MB 8 5 mm 0 33 191 0 mm 7 52 10 5 mm 0 41 37 0 mm 1 46 37 0 mm 1 46 19 5 mm 0 77 50 5 mm 1 99 63 0 mm 2 48 50 5 mm 1 99 82 0 mm...

Страница 11: ...ning direction assuming that the point has not been finely adjusted In the table find the B row of 900 and then follow over to the 6 column and note the number 94 1 mm The approximate opening in the g...

Страница 12: ...utputs with Ethernet SC26 2de XS26 2de 26 convertible I O and 2 redundant solid state safety outputs with display and Ethernet SC10 2roe 10 inputs 2 redundant relay safety outputs 3 contacts each ISD...

Страница 13: ...erity of the operating environment and the frequency of switch actuations Adjust repair or replace components as needed If inspection reveals contamination on the switch thoroughly clean the switch an...

Страница 14: ...lenheim Court Wickford Essex SS11 8YT Great Britain Banner Engineering Corp Limited Warranty Banner Engineering Corp warrants its products to be free from defects in material and workmanship for one y...

Отзывы: