background image

October 10, 2023

S15L Pro In-Line Indicator With ModBus® Instruction Manual 

 

 

11

Chapter Contents

FCC Part 15 Class B .........................................................................................................................................................................................  12
Industry Canada ICES-003(B)...........................................................................................................................................................................  12
Dimensions........................................................................................................................................................................................................  12

 

Supply Voltage

12 V DC to 30 V DC

Supply Current

80 mA maximum current at 12 V DC

35 mA typical at 24 V DC

Supply Protection Circuitry

Protected against reverse polarity and transient voltages

Operating Conditions

–40 °C to +45 °C (–40 °F to +113 °F)

Humidity: 

90% at +50 °C maximum relative humidity (non-

condensing)

Storage Temperature:

 –40 °C to +70 °C (–40 °F to +158 °F)

Environmental Rating

IP65

IP67

IP68

UL Type 1

Construction

Coupling Material: Nickel-plated brass

Connector Body: PVC diffuse white

Vibration and Mechanical Shock 

Meets IEC 60068-2-6 requirements (Vibration: 10 Hz to 55 
Hz, 0.5 mm amplitude, 5 minutes sweep, 30 minutes dwell)

Meets IEC 60068-2-27 requirements (Shock: 15G 11 ms 
duration, half sine wave)

Connections

Integral 4-pin M12 male/female quick-disconnect connector

Models with a quick disconnect require a mating cordset

Required Overcurrent Protection

WARNING: Electrical connections must 
be made by qualified personnel in 
accordance with local and national 

electrical codes and regulations. 

Overcurrent protection is required to be provided by end 

product application per the supplied table. 

Overcurrent protection may be provided with external fusing 
or via Current Limiting, Class 2 Power Supply.

Supply wiring leads < 24 AWG shall not be spliced.

For additional product support, go 

to 

www.bannerengineering.com

Supply 

Wiring 

(AWG)

Required Overcurrent 

Protection (A)

Supply 

Wiring 

(AWG)

Required Overcurrent 

Protection (A)

20

5.0

26

1.0

22

3.0

28

0.8

24

1.0

30

0.5

Default Indicator Characteristics

Color

Dominant 

Wavelength 

(nm) or Color 

Temperature 

(CCT)

Color 

Coordinates

(1)

Lumen 
Output 

(Typical at 

25 °C)

x

y

White

7000K

0.31

0.295

1.16

Green

527

0.175

0.7

1.8

Red

620

0.69

0.307

1.3

Orange

604

0.628

0.356

1.35

Amber

597

0.593

0.383

1.35

Yellow

588

0.537

0.426

1.35

Lime 
Green

577

0.466

0.481

1.8

Spring 
Green

513

0.178

0.562

1.6

Cyan

498

0.195

0.396

1.3

Sky Blue

489

0.17

0.303

1.1

Blue

465

0.144

0.055

0.25

Violet

-

0.337

0.144

0.7

Magenta

-

0.506

0.251

1

Rose

-

0.593

0.282

1.1

Certifications

Banner Engineering BV
Park Lane, Culliganlaan 2F bus 3
1831 Diegem, BELGIUM

(1) 

Refer to the CIE 1931 (x,y) Chromaticity Diagram to show equivalent 

color with indicated color coordinates. Actual coordinates may differ ± 5%.

Specifications

Chapter 4 

© Banner Engineering Corp. All rights reserved.

Содержание S15L Pro

Страница 1: ...S15L Pro In Line Indicator with ModBus Instruction Manual Original Instructions p n 235708 Rev A October 10 2023 Banner Engineering Corp All rights reserved...

Страница 2: ...ng 5 Chapter 3 ModBus Register Map 7 Chapter 4 Specifications FCC Part 15 Class B 12 Industry Canada ICES 003 B 12 Dimensions 12 Chapter 5 Accessories Cordsets 13 Brackets 14 Quick Disconnect Cap 14 C...

Страница 3: ...segment design meets IP65 IP67 and IP68 Connect directly to a compatible sensor or anywhere in the ModBus network for easy visual indication ModBus gives full access to color flashing and intensity s...

Страница 4: ...Blank page 4...

Страница 5: ...Bus Instruction Manual 5 Chapter Contents 4 pin M12 Male 4 pin M12 Female Pin Wire Color Description 1 4 3 2 2 3 4 1 1 Brown 12 V DC to 30 V DC 3 Blue DC Common 4 Black RS 485 2 White RS 485 Wiring Ch...

Страница 6: ...Blank page 6...

Страница 7: ...rial number date code string See Device Yes RO 1038 1053 1039 1054 Serial number string See Device Yes RO Holding Registers to Configure Operation Mode Address without Offset Address with Offset Descr...

Страница 8: ...4 Yellow 5 Lime Green 6 Spring Green 7 Cyan 8 Sky Blue 9 Blue 10 Violet 11 Magenta 12 Rose 13 White 14 Custom 1 15 Custom 2 0 No RW 3313 3314 Color 2 Intensity 0 High 1 Medium 2 Low 3 Off 4 Custom 0 N...

Страница 9: ...key 1 43690 0xAAAA Enable 0 No RW 6602 6603 Restore factory defaults key 2 21845 0x5555 Enable 0 No RW Holding Registers to Configure ModBus Communication Address without Offset Address with Offset De...

Страница 10: ...Blank page 10...

Страница 11: ...ational electrical codes and regulations Overcurrent protection is required to be provided by end product application per the supplied table Overcurrent protection may be provided with external fusing...

Страница 12: ...the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to wh...

Страница 13: ...m 6 56 ft Right Angle 32 Typ 1 26 30 Typ 1 18 14 5 0 57 M12 x 1 7 mm 58 mm 5 2 mm 1 2 3 4 MQDC 415RA 5 m 16 4 ft MQDC 430RA 9 m 29 5 ft MQDC 450RA 15 m 49 2 ft 4 Pin Threaded M12 Cordsets Double Ended...

Страница 14: ...Supplied with thread forming hardware Pack of seven 10 8 12 LMBS15MAG Attaches to S15 housing White polypropylene 11 8 kg 26 lb pull force One piece 19 15 15 33 LMBS15SP Attaches to S15 housing White...

Страница 15: ...INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT WHETHER ARISING IN CONTRACT OR WARRANTY STATUTE TORT STRICT LIABILITY NEG...

Страница 16: ...LinkedIn Twitter Facebook 2023 All rights reserved www bannerengineering com...

Отзывы: