October 10, 2023
S15L Pro In-Line Indicator With ModBus® Instruction Manual
11
Chapter Contents
Supply Voltage
12 V DC to 30 V DC
Supply Current
80 mA maximum current at 12 V DC
35 mA typical at 24 V DC
Supply Protection Circuitry
Protected against reverse polarity and transient voltages
Operating Conditions
–40 °C to +45 °C (–40 °F to +113 °F)
Humidity:
90% at +50 °C maximum relative humidity (non-
condensing)
Storage Temperature:
–40 °C to +70 °C (–40 °F to +158 °F)
Environmental Rating
IP65
,
IP67
,
IP68
,
UL Type 1
Construction
Coupling Material: Nickel-plated brass
Connector Body: PVC diffuse white
Vibration and Mechanical Shock
Meets IEC 60068-2-6 requirements (Vibration: 10 Hz to 55
Hz, 0.5 mm amplitude, 5 minutes sweep, 30 minutes dwell)
Meets IEC 60068-2-27 requirements (Shock: 15G 11 ms
duration, half sine wave)
Connections
Integral 4-pin M12 male/female quick-disconnect connector
Models with a quick disconnect require a mating cordset
Required Overcurrent Protection
WARNING: Electrical connections must
be made by qualified personnel in
accordance with local and national
electrical codes and regulations.
Overcurrent protection is required to be provided by end
product application per the supplied table.
Overcurrent protection may be provided with external fusing
or via Current Limiting, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go
to
www.bannerengineering.com
.
Supply
Wiring
(AWG)
Required Overcurrent
Protection (A)
Supply
Wiring
(AWG)
Required Overcurrent
Protection (A)
20
5.0
26
1.0
22
3.0
28
0.8
24
1.0
30
0.5
Default Indicator Characteristics
Color
Dominant
Wavelength
(nm) or Color
Temperature
(CCT)
Color
Coordinates
(1)
Lumen
Output
(Typical at
25 °C)
x
y
White
7000K
0.31
0.295
1.16
Green
527
0.175
0.7
1.8
Red
620
0.69
0.307
1.3
Orange
604
0.628
0.356
1.35
Amber
597
0.593
0.383
1.35
Yellow
588
0.537
0.426
1.35
Lime
Green
577
0.466
0.481
1.8
Spring
Green
513
0.178
0.562
1.6
Cyan
498
0.195
0.396
1.3
Sky Blue
489
0.17
0.303
1.1
Blue
465
0.144
0.055
0.25
Violet
-
0.337
0.144
0.7
Magenta
-
0.506
0.251
1
Rose
-
0.593
0.282
1.1
Certifications
Banner Engineering BV
Park Lane, Culliganlaan 2F bus 3
1831 Diegem, BELGIUM
(1)
Refer to the CIE 1931 (x,y) Chromaticity Diagram to show equivalent
color with indicated color coordinates. Actual coordinates may differ ± 5%.
Specifications
Chapter 4
© Banner Engineering Corp. All rights reserved.
Содержание S15L Pro
Страница 4: ...Blank page 4...
Страница 6: ...Blank page 6...
Страница 10: ...Blank page 10...
Страница 16: ...LinkedIn Twitter Facebook 2023 All rights reserved www bannerengineering com...