R95C 8-P
ORT
2-C
HANNEL
D
ISCRETE
IO-L
INK
H
UB
I
NSTRUCTION
M
ANUAL
IO-Link®
IO-Link® is a point-to-point communication link between a master device and a sensor and/or light. It can be used to automatically parameterize sensors or lights and
to transmit process data. For the latest IO-Link protocol and specifications, please visit
.
For the latest IODD files, please refer to the Banner Engineering Corp website at:
.
Mechanical Installation
Install the R95C to allow access for functional checks, maintenance, and service or replacement. Do not install the R95C in such a way to allow for intentional defeat.
Fasteners must be of sufficient strength to guard against breakage. The use of permanent fasteners or locking hardware is recommended to prevent the loosening
or displacement of the device. The mounting hole (4.5 mm) in the R95C accepts M4 (#8) hardware. See the figure below to help in determining the minimum screw
length.
CAUTION
:
Do not overtighten the R95C's mounting screw during installation. Overtightening can affect the performance of the R95C.
Wiring
Status Indicators
The R95C 8-Port 2-Channel Discrete Bimodal IO-Link Hub has two matching amber LED indicators, one for each channel, on both sides for each discrete device port
to allow for installation needs and still provide adequate indication visibility. There is also an additional amber LED indicator on both sides of the converter, which is
specific to the IO-Link communication.
Port 1-Port 8 — Female
Pin
Signal Description
1
18 V DC to 30 V DC
2
Discrete 2 (IN/OUT)
3
Ground
4
Discrete 1 (IN/OUT)
Male
Pin
Signal Description
1
18 V DC to 30 V DC
2
Banner-specific
3
Ground
4
IO-Link
17.0 mm
MOUNTING SCREW
2
3
4
1
1
4
3
2