February 12, 2024
Q90R R-GAGE® Radar Sensor Instruction Manual
© Banner Engineering Corp. All rights reserved.
6
Continued from page 5
+
10–30 V DC
D1_Out/IO-Link
D2_Out/**PFM
Input
–
* Push-Pull output. User-configurable PNP/NPN setting.
** Pulse Frequency Modulation
bu (3)
bn (1)
wh (2)
bk (4)
gy (5)
PN
P
NPN
Load
Load
Key:
1 = Brown
2 = White
3 = Blue
4 = Black
5 = Gray (Connect for use with remote input or
Banner Radar Configuration software)
1
4
5
3
2
NOTE: Banner recommends that the shield wire (quick-disconnect cordsets only) be connected to earth
ground or dc common. Shielded cordsets are recommended for all quick-disconnect models.
Dual Discrete Output
Figure 5.
Mount the Device
2.3
If a bracket is needed, mount the device onto the bracket.
1.
Mount the device (or the device and the bracket) to the machine or equipment at the desired location. Do not tighten
the mounting screws at this time.
2.
Check the device alignment.
3.
Tighten the mounting screws to secure the device (or the device and the bracket) in the aligned position.
4.
FINAL DRAFT
Содержание R-GAGE Q90R
Страница 22: ...22 F I N A L D R A F T...
Страница 28: ...28 F I N A L D R A F T...
Страница 32: ...LinkedIn Twitter Facebook 2024 All rights reserved www bannerengineering com F I N A L D R A F T...