![Banner Q5Z Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/banner/q5z/q5z_instruction-manual_3838681019.webp)
June 23, 2023
Q5Z Global Laser Measurement Sensor With IO-Link Instruction Manual
19
Chapter Contents
6.1 Two-Point Static Background Suppression ................................................................................................................................................. 19
6.2 Dynamic Background Suppression ............................................................................................................................................................. 20
6.3 One-Point Window (Foreground Suppression) ........................................................................................................................................... 21
6.4 One-Point Background Suppression ........................................................................................................................................................... 23
6.5 Dual (Int Distance) .......................................................................................................................................................................... 24
Use the following procedures to teach the sensor.
Channel 2 can be taught only if the sensor has been configured for channel 2 to be light operate or dark operate. To change
the active channel, press the
TEACH
five times. The LED indicator of the nowactivated channel flashes five times and can
be taught normally. The teach method of both channels is the same.
NOTE:
If the TEACH procedure is in process, it can be canceled by pressing the
TEACH
button for longer
than 2 seconds or by holding the remote input high for longer than 2 seconds.
Twopoint TEACH sets a single switch point.
The sensor sets the switch point between two taught target distances, relative
to the shifted origin location.
1
4
2
3
5
TEACH Procedures
Chapter 6
Two-Point Static Background Suppression
6.1
Two-Point Static Background Suppression (Light Operate shown)
Figure 18.
Present the target.
Method
Action
Result
Push Button
Present the first target. The sensor-to-target distance must be within the
sensor's range.
Remote Input
1.
Start the TEACH mode.
Method
Action
Result
Push Button
Press and hold
TEACH
for longer than 2 seconds.
The indicator of the active channel flashes.
Remote Input
No action required.
N/A
2.
Teach the sensor.
3.
© Banner Engineering Corp.
Содержание Q5Z
Страница 4: ...Blank page 4...
Страница 8: ...Blank page 8...
Страница 16: ...Blank page 16...
Страница 26: ...Blank page 26...
Страница 34: ...Blank page 34...
Страница 38: ...Blank page 38...
Страница 41: ...LinkedIn Twitter Facebook 2023 All rights reserved www bannerengineering com...