June 23, 2023
Q5Z Global Laser Measurement Sensor With IO-Link Instruction Manual
28
Beam Spot Size
x
y
Beam
Spot
Pattern
Distance (mm)
Size (x × y) (mm)
100
3.8 × 5.0
1000
5.2 × 6.5
1800
7.0 × 6.2
Beam spot size is calculated as 1.6 times the D4σ measured
value
Discrete Output Distance Repeatability
Distance (mm)
Repeatability (1800 mm Mod
els)
95 to 300
± 0.5 mm
300 to 1000
± 0.25%
1000 to 1800
± 0.52%
Required Overcurrent Protection
WARNING: Electrical connections must
be made by qualified personnel in ac
cordance with local and national electri
cal codes and regulations.
Overcurrent protection is required to be provided by end prod
uct application per the supplied table.
Overcurrent protection may be provided with external fusing
or via Current Limiting, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go
to
www.bannerengineering.com
.
Supply
Wiring
(AWG)
Required Overcurrent
Protection (A)
Supply
Wiring
(AWG)
Required Overcurrent
Protection (A)
20
5.0
26
1.0
22
3.0
28
0.8
24
1.0
30
0.5
Typical Excess Gain
High Excess Gain (Standard Excess Gain) Using a 90%
White Card
(1)
Response
Speed (ms)
at 100 mm
at 500 mm
at 1000 mm
at 1800 mm
3
100
40
12
3
5
100
40
12
3
15
460 (140)
220 (65)
55 (20)
10 (5)
25
800 (520)
400 (220)
100 (55)
25 (12)
50
1600 (800)
800 (400)
200 (100)
50 (25)
Certifications
Banner Engineering BV
Park Lane, Culliganlaan 2F bus 3
1831 Diegem, BELGIUM
Class 2 power; UL Environmental Rating: Type 1
Advanced Capabilities
(1)
Standard excess gain is available in 15, 25, and 50 ms response speeds;
standard excess gain provides increased noise immunity.
© Banner Engineering Corp.