P/N 69761 rev. B
27
Banner Engineering Corp.
•
Minneapolis, U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
PICO-GUARD Controller
Instruction Manual
System Operation
Channel Latch
1: An Optical Channel Latch has occurred.
0: An Optical Channel Latch has not occurred or has been reset.
USSI 1 Latch
1: USSI 1 Latch has occurred.
0: USSI 1 Latch has not occurred or has been reset.
EDM 2 Open
1: EDM 2 Input is Open (low).
0: EDM 2 Input is Closed (high).
EDM 2 Noisy
1: Noise detected on EDM 2 Input.
0: No noise detected on EDM 2 Input.
EDM 1 Open
1: EDM 1 Input is Open (low).
0: EDM 1 Input is Closed (high).
EDM 1 Noisy
1: Noise detected on EDM 1 Input.
0: No noise detected on EDM 1 Input.
USSI 1 Reset Closed
1: USSI 1 Reset Input is Closed (high).
0: USSI 1 Reset Input is Open (low).
USSI 1 Reset Noisy
1: Noise detected on USSI 1 Reset Input.
0: No noise detected on USSI 1 Reset Input.
System Reset Close
d
1: System Reset Input is Closed (high).
0: System Reset Input is Open (low).
System Reset Noisy
1: Noise detected on System Reset Input.
0: No noise detected on System Reset Input.
One-Channel EDM
(Config Invalid bit must be 0)
1: EDM Switches are set to “1”; system is set for one-channel EDM.
0: EDM Switches are set to “2” and
Two-Channel EDM bit = 1 – system is set for two-channel EDM.
Two-Channel EDM bit = 0 – system is set for No EDM.
Trip Mode Selected
(Config Invalid bit must be 0)
1: Trip/Latch Switches are set to “T”; Trip output selected.
0: Trip/Latch Switches are set to “L”; Latch output selected.
Auto Power-up
(Config Invalid bit must be 0)
1: Auto/Man Switches are set to “Auto”; system is set for Auto
Power-up.
0: Auto/Man Switches are set to “Man”; system is set for Manual
Power-up.
Configuration Invalid
1: The system configuration is invalid or unknown (not available).
0: The system configuration is valid.
Aux Output
1: ON
0: OFF
Weak Output
1: ON
0: OFF
Fault Output
1: ON
0: OFF
System Status
001: The PICO-GUARD is in Manual Power-up mode and is
waiting for a System Reset.
010: The PICO-GUARD is in a Latched Condition
011: The PICO-GUARD is in a Run Condition
100: The PICO-GUARD is in a Lockout Condition
101: The PICO-GUARD is in a Power-up Condition
OSSD1 State Invalid
1: The state of the OSSD1 Output is unknown (not available).
0: The state of the OSSD1 Output is known.
OSSD1 OC Fault Invalid State
1: The state of the OSSD1 OC Fault is unknown (not available).
0: The state of the OSSD1 OC Fault is known.
OSSD1 State
1: ON
0: OFF
OSSD1 OC Fault
1: OSSD1 Overcurrent Fault has been detected.
0: OSSD1 Overcurrent Fault has not been detected.
OSSD2 State Invalid
1: The state of the OSSD2 Output is unknown (not available).
0: The state of the OSSD2 Output is known.
OSSD2 OC Fault Invalid State
1: The state of the OSSD2 OC Fault is unknown (not available).
0: The state of the OSSD2 OC Fault is known.
OSSD2 State
1: ON
0: OFF
OSSD2 OC Fault
1: OSSD2 Overcurrent Fault has been detected.
0: OSSD2 Overcurrent Fault has not been detected.
Number of Optical Channels
The total number of optical channels of the controller. A value of 4
indicates a 4-channel controller.
System Noise Detected
1: Noise detected.
0: No noise detected.
Two-Channel EDM
1: Two-Channel EDM selected.
0: One-Channel EDM bit = 1: One-Channel EDM selected.
One-Channel EDM bit = 0: No EDM selected.
4.6.1 Diagnostic Data Explanations