PICO-AMP Miniature Remote Sensing System
SP3/SP8 Remote Sensor Hookups
Mounting the Sensors
Opposed-mode sensors are shipped in connected pairs (one emitter and one
receiver), with a 6' cable attached; the cable comes split to 6"; it may be split further
as needed to allow sufficient sensor separation.
The sensors may be through-mounted to a wall using the hardware included with the
sensors. Using the provided 8 mm long screws, SP3 sensors may mount to a
maximum wall thickness of 4.0 mm (0.16"); SP8 sensors may mount to a maximum
wall thickness of 3.2 mm (0.13"). If mounted to the threaded accessory mounting
bracket, only the screws need be used.
8 mm
Stainless Steel
Screws
Nut
Lock Washer
Washer
Max. Wall Thickness
3.2 mm (SP8) or
4.0 mm (SP3)
8 mm
Stainless Steel
Screws
SHIELD
WHITE
RED
SHIELD
To Emitter
From Receiver
MD14 Series Amplifier
Figure 3. Mounting the SP3/SP8 sensor to
a wall
Figure 4. Mounting the SP3/SP8 sensor to
its accessory mounting bracket
(see page 7)