![Banner LS2e30-1050Q8 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/banner/ls2e30-1050q8/ls2e30-1050q8_instruction-manual_472043018.webp)
Receiver
Emitter
Receiver
Emitter
Receiver
Emitter
Both cable ends down
Both cable ends up
Orientation parallel to floor with both
cable ends pointing in the same
direction
Figure 7. Examples of Correct Emitter/Receiver Orientation
Receiver
Emitter
Receiver
Emitter
Cable ends point in opposite directions
Problem: Voids in defined area
Emitter and receiver not parallel to each other
Problem: Reduced excess gain
Figure 8. Examples of Incorrect Emitter/Receiver Orientation
Installation of Multiple Systems
Whenever two or more EZ-SCREEN Type 2 emitter and receiver pairs are adjacent to one another, optical crosstalk may
take place between the systems. To minimize optical crosstalk, alternate the positions of the emitters and receivers (see
Figure 9
on page 19).
When three or more systems are installed in the same plane (as shown in
Figure 9
on page 19), optical crosstalk may
occur between sensor pairs whose emitter and receiver lenses are oriented in the same direction. In this situation,
eliminate optical crosstalk by mounting these sensor pairs exactly in line with each other within one plane, or by adding a
mechanical barrier between the pairs.
EZ-SCREEN
®
Type 2 Light Screen
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]