Figure 3. Safety distance (minimum distance) and hard (fixed) guarding
EZ-SCREEN Type 2 Models With Response Times
Models (see note below)
Defined Area Height
Number of Beams
Response Time (Tr)
LS2..30-150Q8
150 mm (5.9 in)
8
11 ms
LS2..30-300Q8
300 mm (11.8 in)
16
13 ms
LS2..30-450Q8
450 mm (17.7 in)
24
14 ms
LS2..30-600Q8
600 mm (23.6 in)
32
16 ms
LS2..30-750Q8
750 mm (29.5 in)
40
17 ms
LS2..30-900Q8
900 mm (35.4 in)
48
19 ms
LS2..30-1050Q8
1050 mm (41.3 in)
56
21 ms
LS2..30-1200Q8
1200 mm (47.2 in)
64
22 ms
LS2..30-1350Q8
1350 mm (53.1 in)
72
24 ms
LS2..30-1500Q8
1500 mm (59 in)
80
25 ms
LS2..30-1650Q8
1650 mm (65 in)
88
27 ms
LS2..30-1800Q8
1800 mm (70.9 in)
96
29 ms
NOTE: The .. in the model numbers is one of the following:
•
E = Emitter
•
TR = Trip-Output Receiver
•
LR = Latch-Output Receiver
•
TP = Trip-Output Emitter/Receiver Pair
•
LP = Latch-Output Emitter/Receiver Pair
Pair model numbers end in 88 (for example, LS2TP30-150Q88) to indicate that both the transmitter
and receiver have an 8-pin connector.
Formula and Examples
U.S. Applications
European Applications
The Safety (Separation) Distance formula for U.S. applications:
Ds = K × (Ts + Tr) + Dpf
The Minimum Distance formula for European applications:
S = (K × T) + C