June 22, 2023
LTF Time Of Flight Laser Distance Sensor With IO-Link Instruction Manual
21
Window TEACH Offset
Use the
D_OUT
›
TchMid
›
Offset
menu to set an offset from the taught distance used during a Midpoint TEACH. By default,
the value is 0 mm because the window is centered around the taught distance. A positive offset value always shifts the win-
dow towards the sensor.
Adjust Switch Point One
The AdjSPt1 option manually adjusts the value of the switch point one threshold for the Discrete Output when the sensor is in
Window mode. The value is adjustable within the sensor's range. It is required to be maintain the minimum window size be-
tween switch points. This menu is not available when the sensor is in Switch, Alarm, or Health mode.
Remote Input
: Not available
Default
: 50 mm
Adjust Switch Point Two
The AdjSPt2 option manually adjusts the value of the switch point two threshold for the Discrete Output when the sensor is in
Window mode. The value is adjustable with the sensor's range. It is required to be maintain the minimum window size be-
tween switch points. This menu is not available when the sensor is in Switch, Alarm, or Health mode.
Remote Input
: Not available
Default
: 12000 mm for LTF12; 24000 mm for LTF24
TEACH Switch Point
The TchSPt option teaches the distance at which the switch point threshold is placed when the Discrete Output is in Switch
mode. This menu is not available when the sensor is in Window, Alarm, or Health mode.
Navigate
:
MENU
›
Dx_OUT
›
TchSPt
Remote Input
: Available
Button Instructions
Action
Result
Present the target.
"RMT TCH" and the target's measurement
value display.
TEACH the sensor.
Action
Result
Five-pulse the remote input.
T
T
T
T
T
T
T
T
T
"TchMdpt Teaching
" displays while the sen-
sor is being taught.
TEACH Accepted
The new value displays on the second line
of the display, flashes, and the sensor re-
turns to Run mode.
TEACH Not Accepted
"
FAIL" and a warning message display, the
sensor returns to step 2, and "RMT TCH"
displays.
3.
Present the target.