Quick Start Guide
Laser displacement sensor that supports IO-Link communication with analog and discrete (switched) outputs.
This guide is designed to help you set up and install the L-GAGE LM Analog/Discrete Laser Sensor. For complete information on
programming, performance, troubleshooting, dimensions, and accessories, please refer to the Instruction Manual at
www.bannerengineering.com
. Search for p/n 205812 to view the manual. Use of this document assumes familiarity with pertinent
industry standards and practices.
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or
death. This device does not include the self-checking redundant circuitry necessary to allow its use in
personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized
sensor output condition.
Features and Indicators
1
3
2
Three LED indicators provide ongoing indication of the sensing status.
1. Analog Output LED Indicator
Solid Amber = Displayed distance is within the taught analog output window
Off = Displayed distance is outside the taught analog output window
2. Power LED Indicator
Solid Green = Normal operation, power On and laser On
Flashing Green (1 Hz) = Power On and laser Off (laser enable mode)
3. Discrete Output LED Indicator
Solid Amber = Discrete Output is On
Off = Discrete Output is Off
Laser Description and Safety Information
CAUTION: Use of controls or adjustments or performance of procedures other than those specified herein may
result in hazardous radiation exposure. Do not attempt to disassemble this sensor for repair. A defective unit
must be returned to the manufacturer.
Class 2 Laser Models
CAUTION: Never stare directly into the sensor lens. Laser light can damage your eyes. Avoid placing any
mirror-like object in the beam. Never use a mirror as a retroreflective target.
For Safe Laser Use - Class 2 Lasers
•
Do not stare at the laser.
•
Do not point the laser at a person’s eye.
•
Mount open laser beam paths either above or below eye level, where practical.
•
Terminate the beam emitted by the laser product at the end of its useful path.
Reference IEC 60825-1:2007, Section 8.2.
L-GAGE
®
LM Series Laser Sensor
Original Document
205811 Rev. B
27 August 2018
205811