![Banner L-GAGE LM Series Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/banner/l-gage-lm-series/l-gage-lm-series_quick-start-manual_4028319007.webp)
Specifications
Supply Voltage (Vcc)
10 V dc to 30 V dc
Power and Current Consumption, exclusive of load
Normal Run Mode: 1.5 W, Current consumption < 62 mA at 24 V dc
Supply Protection Circuitry
Protected against reverse polarity and transient overvoltages
Ambient Light Immunity
10,000 lux
Sensing Beam
Visible red, 655 nm
Sensing Range
50 mm to 150 mm
Delay at Power Up
2.1 s
Measurement/Output Rate
0.25 ms to 4 ms; user selectable from the Speed menu
Output Configuration
Analog output: 4 to 20 mA
Discrete output: Push/Pull, IO-Link
Output Ratings
Discrete Output: 50 mA maximum (protected against continuous
overload and short circuit)
Output saturation voltage (PNP): < 3 V at 50 mA
Output saturation voltage (NPN): < 2.5 V at 50 mA
Analog current output (LM...I Models): 500 Ω maximum
Minimum Window Size, Analog and Discrete
Analog: 1 mm
Discrete: 0.1 mm
Boresighting
± 0.87 mm at 50 mm
± 2.62 mm at 150 mm
Maximum Torque
1.5 N·m
Remote Input
Allowable Input Voltage Range: 0 to Vcc
Active Low (internal weak pullup—sinking current):
High State: > 3.6 V
Low State: < 2.4 V
Active High (internal weak pulldown—sourcing current):
High State: > Vcc - 2.9 V
Low State: < Vcc - 4.6 V
Analog Resolution
0.004 mm
Analog and IO-Link Linearity
50 mm to 120 mm: ± 0.060 mm
120 mm to 150 mm: ± 0.070 mm
Repeatability
± 0.002 mm 1
Temperature Effect, Typical
± 0.008 mm/deg C
IO-Link Accuracy
± 0.2 mm
Construction
Housing: stainless steel
Window: acrylic
Vibration/Mechanical Shock
Meets IEC 60947-5-2 (10 to 60 Hz max., double amplitude 0.06
in, max acceleration 10G. 30G 11 ms duration, half sine wave)
Typical Beam Spot Size2
x
y
Beam
Spot
Pattern
Distance (mm)
50
100
150
x
2.12
1.44
0.77
y
0.68
0.49
0.31
Response Time
Total response speed varies from 0.5 ms to 2048 ms, depending
on base measurement rate and averaging settings.
See Instruction Manual for more information.
Minimum Object Separation
Uniform targets (6% to 90% reflectivity):
50 mm to 120 mm: 0.120 mm
120 mm to 150 mm: 0.140 mm
Non-uniform targets (6% to 90% reflectivity): 0.8 mm.
1 Performance with 6% to 90% reflectivity with 64× averaging. With 1× averaging, repeatability of ± 0.005 mm from 50 mm to 120 mm and
± 0.010 mm from 120 to 150 mm.
2 Beam spot size is the D4
σ
measured value
L-GAGE
®
LM Series Laser Sensor
P/N 205811 Rev. B
www.bannerengineering.com - Tel: +1-763-544-3164