background image

 

June 22, 2023

page 

4

K30 Pro Optical Sensor Quick Start Guide

Specifications

Supply Voltage (Vcc)

10 V DC to 30 V DC

Supply Current

110 mA maximum current at 30 V DC (exclusive of load)
30 mA typical current at 24 V DC (exclusive of load)

Supply Protection Circuitry 

Protected against output short-circuit

 

Leakage Current Immunity

400 µA

Range 

The sensor can detect an object at the following ranges, de­

pending on the material and size of the target: 20 mm to 1000 
mm

Output Ratings

 Maximum Load

: 150 mA

ON-State Saturation Voltage:

< 2 V DC at 10 mA 
< 2.5 V DC at 150 mA 

OFF-State Leakage Current: < 10 µA at 30 V DC

Remote Input

Allowable Input Voltage Range: 0 to Vsupply
Active High (internal weak pull-down): High state > (Vsupply - 
2.25 V) at 2 mA maximum
Active Low (internal weak pull-up): Low state < 2.25 V at 2 mA 

maximum 

Mounting

 M22 × 1.5 threaded base, maximum torque 4.5 N·m (40 

in·lbf)

Construction 

Base, Dome, and Nut: Polycarbonate

Connections 

Integral 5-pin or 8-pin M12 male quick-disconnect connector
Models with a quick disconnect require a mating cordset

NOTE: A shielded cable is required if the 

sensor is mounted outdoors or if the ca­
ble is longer than 30 m (98.4 ft). 

Vibration and Mechanical Shock 

 

All models meet MIL-STD-202F, Method 201A (Vibration: 10 

Hz to 60 Hz maximum, 0.06 inch (1.52 mm) double amplitude, 

10G acceleration) requirements. 

Method 213B conditions 

H&I.

Shock: 75G with device operating; 100G for non­opera­

tion

 

Operating Temperature 

 –20 °C to +50 °C (–4 °F to +122 °F)

Storage Temperature

–40 °C to +70 °C (–40 °F to +158 °F)

Sensing Beam

Infrared, 940 nm

Delay at Power­up 

< 1 s

Response Time 

Switching frequency: 4 Hz
Discrete output response: 120 ms

Remote Input Map

0.04 seconds < T < 0.8 seconds

Timing between pulse less than 1 second

Pulse Timing (T)

Gray/Yellow wire is remote teach input

Remote 

Input

3x

Object Mode Teach

1x

Confirm Teach

4x

Background Mode Teach

1x

Confirm Teach

5x

Window Mode Teach

1x

Confirm Teach

7x

Enable/Disable Remote Teach

1x

Confirm Enable/Disable

9x

Reset to Factory Defaults

1x

Confirm Factory Reset

© Banner Engineering Corp.

Содержание K30 Pro

Страница 1: ...nt to ambient light EMI and RFI interference Sensing and indication in one device WARNING Do not use this device for personnel protection Using this device for personnel protection could result in ser...

Страница 2: ...te Input 1 Pin 1 Brown Pin 2 White Pin 3 Blue Pin 4 Black Pin 5 Gray Remote Input GRY4 Four State Full Logic No Detection Detection No Input State 1 Indicator Off State 3 Indicator Red Input 1 State 2...

Страница 3: ...ed in this manual Remote teach can also be performed using the button on the Pro Converter Cable The length of the individual programming pulses is equal to the value T 0 04 seconds T 0 8 seconds Exit...

Страница 4: ...nections Integral 5 pin or 8 pin M12 male quick disconnect connector Models with a quick disconnect require a mating cordset NOTE A shielded cable is required if the sensor is mounted outdoors or if t...

Страница 5: ...ntrol F2 Mode Four State Full Logic Custom Pro Converter Cable required to interface between PC and in dicator see accessories Required Overcurrent Protection WARNING Electrical connections must be ma...

Страница 6: ...y Banner Engineering Corp will void the prod uct warranties All specifications published in this document are subject to change Banner reserves the right to modify product specifications or update doc...

Страница 7: ...K30 Pro Optical Sensor Quick Start Guide June 22 2023 page 7 Original Instructions Banner Engineering Corp All rights reserved 232898 Banner Engineering Corp...

Отзывы: