© Banner Engineering Corp. www.bannerengineering.com
3
B
ANNER
E
NGINEERING
C
ORP
K30 P
RO
O
PTICAL
S
ENSOR
I
NSTRUCTION
M
ANUAL
Configuring a Sensor
The K30 Pro Optical Sensor has three Teach modes. These modes are indicated with a Teach Status color.
The Signal Level color flashes in between the Teach Status color. The color of the Signal Level depends on the signal strength of the target:
Green: Best signal, accepts Teach
Yellow: Acceptable signal, can accept Teach
Red: Poor signal, rejects Teach
Remote Input
Use the remote input to program the sensor remotely.
The remote input provides limited programming options and is Active High in PNP mode (V+ to brown wire), or Active Low in NPN mode (V+ to blue wire). For Active
High, pulse the gray or yellow input wire to V+ (10 V DC to 30 V DC). For Active Low, pulse the gray or yellow input wire to ground (0 V DC).
The remote input wire is enabled by default. Pulse the remote input wire 7 times or use the Banner Pro Editor software to enable or disable the feature. When the
remote input feature is enabled, pulse the remote input according to the diagram and the instructions provided in this manual. Remote teach can also be performed
using the button on the Pro Converter Cable.
The length of the individual programming pulses is equal to the value T:
0.04 seconds ≤ T ≤ 0.8 seconds
.
Exit remote programming modes by cycling power or by waiting for 30 seconds.
NOTE
:
If a factory reset is performed through the Banner Pro Editor Software, the remote input wire becomes enabled (factory default setting). If the sensor is returned
to factory defaults by using the remote input wire, the input wire remains enabled and the rest of the settings are restored to factory defaults.
Remote Teach
Use the following procedure to teach the Set Point.
1.
Pulse the remote input:
•
3x - Object Teach: The indicator alternates between a blue Teach Status color and the Signal Level color.
•
4x - Background Teach: The indicator alternates between a magenta Teach Status color and the Signal Level color.
•
5x - Window Teach: The indicator alternates between a cyan Teach Status color and the Signal Level color.
2.
Present the Set Point.
3.
Teach the Set Point.
Table 5:
RGB7 Models
Figure 5:
NPN
Figure 6:
PNP
Pin 1 = White
Pin 2 = Brown
Pin 3 = Green
Pin 4 = Yellow (Remote
Input)
Pin 5 = Not used
Pin 6 = Not used
Pin 7 = Blue
Pin 8 = Red
Table 6:
RGB Multicolor Color/Function Definition
Red
Yellow
Green
Cyan
Blue
Magenta
White
Input 1
X
X
X
X
Input 2
X
X
X
X
Input 3
X
X
X
X
Action
Result
Single pulse the remote input.
Teach Accepted
The indicator stops flashing and the device returns to operation.
Teach Not Accepted
The Signal Level color turns red during the teach procedure, and
then the indicator stops flashing.
Retry teaching the set point.
2
7
–
+
1
3
4
8
1
2
3
Load
10-30V dc
2
7
–
+
1
3
4
8
1
2
3
Load
10-30V dc
T