Accessory and Replacement Parts

Mounting hole for M5

(2- 5.3)

Coating

86

50

81

20

33

Material: SUS304

Thickness: t=3.0 mm

Model
ED9Z-GH1

 Right-angle bracket

Right-angle bracket mounts directly to upright surface, holds enabling switch for

easy access when needed. All measurements in mm.

Rubber boot

Model
ED9Z-GBK1-1N

 NBR/PVC gray Polyblend boot

Identical to original boot shipped with enabling device.

EC Declaration of Conformity

Banner Engineering Corp. herewith declares that the ED1G Series Enabling Device is in conformity with the provisions of the Machinery

Directive (Directive 2006/42/EC), and all essential Health and Safety Requirements have been met. Download the complete EC Declara-

tion of Conformity as a PDF file a

www.bannerengineering.com/Enable_Device

Contact Us

For more information: Contact your local Banner representative or Banner Corporate Offices around the world.

Corporate Headquarters: Banner Engineering Corp.

 9714 Tenth Ave. North, Mpls., MN 55441, Tel: 763-544-3164, 

www.bannerengin-

eering.com

[email protected]

Europe: Banner Engineering Europe

 Park Lane, Culliganlaan 2F, Diegem B-1831 BELGIUM,Tel: 32-2 456 07 80, Fax: 32-2 456 07 89, 

www.bannereurope.com

[email protected]

Latin America: 

Contact Banner Engineering Corp. (US) or e-mail 

Mexico:

 

[email protected]

; or 

Brazil: 

brasil@banner-

engineering.com

Asia:
Banner Engineering China

 Shanghai Rep Office Rm. G/H/I, 28th Flr. Cross Region Plaza No. 899, Lingling Road, Shanghai 200030

CHINA, Tel: 86-21-54894500, Fax: 86-21-54894511, 

www.bannerengineering.com.cn

[email protected]

Banner Engineering Japan

 Cent-Urban Building 305 3-23-15, Nishi-Nakajima Yodogawa-Ku, Osaka 532-0011 JAPAN, Tel:

81-6-6309-0411, Fax: 81-6-6309-0416

www.bannerengineering.co.jp

[email protected]

Banner Engineering Asia   Taiwan

 Neihu Technology Park 5F-1, No. 51, Lane 35, Jihu Rd., Taipei 114 TAIWAN, Tel:

886-2-8751-9966, Fax: 886-2-8751-2966, 

www.bannerengineering.com.tw

[email protected]

Banner Engineering India

 Pune Head Quarters Office, No. 1001 Sai Capital, Opp. ICC Senapati Bapat Road, Pune 411016 INDIA, Tel:

91-20-66405624, Fax: 91-20-66405623, 

www.bannerengineering.co.in

[email protected]

 

 

ED1G Enabling Switch

 

 

Warranty: Banner Engineering Corporation warrants its products to be free from defects

for a period of one year. Banner Engineering Corporation will repair or replace, free of

charge, any product of its manufacture found to be defective at the time it is returned to

the factory during the warranty period. This warranty does not cover damage or liability

for the improper application or installation of Banner products. This warranty is in lieu of

any other warranty either expressed or implied.

Содержание ED1G

Страница 1: ...dard ANSI B11 19 Performance Criteria for Safeguards ANSI NFPA 79 2007 and IEC 60204 1 2000 Electrical Re quirements for Industrial Machines Enabling switch left and Enabling switch with integral mome...

Страница 2: ...FPA 79 Electrical Standard for Industrial Machinery ANSI RIA R15 06 Safety Requirements for Industrial Robots and Robot Systems ANSI PMMI B155 1 Package Machinery and Packaging Related Converting Mach...

Страница 3: ...otherwise be safeguarded Each enabling device must be concurrently operated before machine motion can be initiated The enabling device is not considered to be an emergency stop device but if performin...

Страница 4: ...o be bypassed Initiation of motion should only be through a hold to run type of control All emergency stops must remain active The means of bypassing must be employed at the same level of reliability...

Страница 5: ...nd must comply with the relevant electrical standards and wiring codes such as the NEC National Electrical Code ANSI NFPA79 or IEC 60204 1 and all applicable local standards and codes Lockout tagout p...

Страница 6: ...series connected see wiring diagram and the following warning WARNING Multiple Switching Devices Whenever two or more devices are connected to the same safety module controller Contacts of the corres...

Страница 7: ...m L2 27 mm Wire Stripping Length L3 L3 6 mm Terminal No Connector Base L1 L2 L3 L3 Figure 3 Wire lengths to terminal connections 5 Replace the cover and secure with the three screws torque 1 1 to 1 3...

Страница 8: ...S21 S22 S12 13 23 33 S31 S32 24 14 34 44 43 A2 S34 S33 Functions requiring bypass Functions not requiring bypass Machine Control Circuits 5 6 1 Selection of the enabling device must be capable of bei...

Страница 9: ...the interconnect cabling for crushing cuts or wear 2 Inspect the device for loosening or damage to the mounting hardware or means of storage 3 With the enabling device selected e g bypass or maintenan...

Страница 10: ...ons minimum Operating frequency 1 200 operations per hour max imum Electrical Life 100 000 operations minimum at rated load Pollution Degree 3 Terminal Pulling Strength 20 N minimum Terminal Screw Tor...

Страница 11: ...esistive load AC 12 2 A 1 A Inductive load AC 15 1 A 0 5 A DC Resistive load DC 12 2 A 0 4 A 0 2 A Inductive load DC 13 1 A 0 22 A 0 1 A Rated Current le Mo mentary push button switch Terminals 7 8 mo...

Страница 12: ...p US or e mail Mexico mexico bannerengineering com or Brazil brasil banner engineering com Asia Banner Engineering China Shanghai Rep Office Rm G H I 28th Flr Cross Region Plaza No 899 Lingling Road S...

Отзывы: