![Banner E-Stop ES-TN-14H5 Скачать руководство пользователя страница 1](http://html.mh-extra.com/html/banner/e-stop-es-tn-14h5/e-stop-es-tn-14h5_instruction-manual_471820001.webp)
E-Stop Safety Modules with Adjustable Delay
®
Models
ES-TN-14H5
with 0-20 second delay,
ES-TN-14H6
with 0-200 second delay
Features
• Selectable Auto-Reset or monitored Manual Reset.
• Auto or manual power-up
• One- or two-channel feedback monitoring
• Monitors one dual-channel or one single-channel normally closed E-stop switch
circuit for a contact failure or wiring fault (safety category 2 or 4,
per ISO13849-1 [EN954-1]; see pages 5-7).
• 4 amp safety output contacts
• Removable terminal blocks
• Input monitoring circuit has diverse-redundant microprocessors
• Designed for use in functional stop Category 0 and 1 applications (per ISO/EN
60204-1 and NFPA79)
• Four immediate output switching channels (functional stop Category 0) and four
delayed output switching channels (functional stop Category 1). Delay time is
adjustable from 0-20 seconds or 0-200 seconds, depending on model.
• One auxiliary non-safety, normally closed immediate output and one auxiliary
non-safety normally closed delayed output for status monitoring.
WARNING . . .
This Emergency Stop
Safety Module is not
a point-of-operation
guarding device, as
defined by OSHA regulations.
It
is necessary to install point-of-
operation guarding devices, such
as safety light screens and/or hard
guards, to protect personnel from
hazardous machinery.
Failure to
install point-of-operation guards
on hazardous machinery can
result in a dangerous condition
which could lead to serious
injury or death.
!