background image

Factory Default Settings:

Setting

Factory Default

Threshold

3700 (typical)

TEACH Selection

Window SET

Response Speed

Standard: 250 µs

Offset Percent

2%

Totalizer Counts

OFF

Totalizer One-Shot

OFF

Dynamic Event Stretcher

50%

Display Readout

Numeric, ECO disabled, Normal Orientation

Adjust Mode 

Sliding the RUN/PRG/ADJ mode switch to the ADJ position allows the user to perform Expert TEACH/SET methods.

TEACH Procedures

The instruction manual has detailed instructions for these TEACH modes:

Window SET

Light SET

Dynamic TEACH

Window SET

Sets window thresholds that extend a programmable % offset above and below the presented condition

All other conditions (lighter or darker) cause the output to change state

Recommended for applications where a product may not always appear in the same place, or when other signals

may appear

See Program Mode in the user's manual for programming the Offset Percent setting (to increase/decrease the

window size)

A single sensing condition is presented, and the sensor positions window thresholds a programmable % offset above and

below the presented condition. In LO mode, Window SET designates a sensing window with the Output ON condition inside

the window, and the Output OFF conditions outside the window.

Sensor positions 
window thresholds 

a programmable %
offset from the 

presented condition

Darkest

(no signal)

Most Light

(saturated

signal)

Condition 

Presented

Sensing Window

Output OFF

Output OFF

Output ON

Figure 3. Window SET (Light Operate shown)

Output ON and OFF conditions can be reversed using the LO/DO switch.

Light SET

Sets a threshold a programmable % offset below the presented condition

Changes output state on any condition darker than the threshold condition

Recommended for applications where only one condition is known, for example a stable light background with

varying darker targets

See 

Program Mode 

on page 5 for programming the Offset Percent setting

 

 

DF-G2 High Speed Expert

 Dual Display Small Object Counter

6

www.bannerengineering.com - Tel: +1-763-544-3164

P/N 178061 Rev. E

Содержание DF-G2 High Speed Expert

Страница 1: ...vel 6 Green Threshold 7 SET Rocker Button Models Model Outputs Connector1 DF G2 NC 2M Single NPN plus Health Mode output 2 m 6 5 ft cable 5 wire DF G2 PC 2M Single PNP plus Health Mode output DF G2 NC...

Страница 2: ...the DF G2 up on the DIN rail 1 3 Pivot the DF G2 onto the DIN rail pressing until it snaps into place 2 Mount to the Accessory Bracket 1 Position the DF G2 in the SA DIN BRACKET 2 Insert the supplied...

Страница 3: ...nstall the fiber adapter provided with the fiber assembly to ensure a reliable fit in the fiber holder Banner includes the adapters with all fiber assemblies TO FIBERS TO SENSOR Fiber Outer Diameter m...

Страница 4: ...output is ON when the sensing condition is above the threshold For Window SET the output is ON when the sensing condition is inside the window In Dark Operate mode the output is ON when the sensing co...

Страница 5: ...counts value to reset to 0 Program Mode or to set value or to set value or to set value display flips 180 Click SET to enter choice list Press and hold SET to exit choice list without saving DISPLAY...

Страница 6: ...ease decrease the window size A single sensing condition is presented and the sensor positions window thresholds a programmable offset above and below the presented condition In LO mode Window SET des...

Страница 7: ...t OFF Output ON Darkest Taught Condition Lightest Taught Condition Position Figure 5 Dynamic TEACH Light Operate shown The output ON and OFF conditions can be reversed using the LO DO switch Troublesh...

Страница 8: ...econds Return the system to normal operation by cleaning the fiber optic array and performing a Window SET to reset the clear state light level see Window SET on page 6 Specifications Sensing Beam Vis...

Страница 9: ...warranty period This warranty does not cover damage or liability for misuse abuse or the improper application or installation of the Banner product THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF AL...