![Banner DF-G2 High Speed Expert Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/banner/df-g2-high-speed-expert/df-g2-high-speed-expert_quick-start-manual_3710814002.webp)
Fiber Optic Arrays
Models 2
Detection Window
Dimensions
Fiber Exit
Minimum Object Size 3
PFCVA-10X25-S
10 mm x 25 mm
Side exit
1.5 mm
PFCVA-10X25-E
End exit
PFCVA-25X25-S
25 mm x 25 mm
Side exit
3 mm
PFCVA-25X25-E
End exit
PFCVA-34X25-S
34 mm x 25 mm
Side exit
4 mm
PFCVA-34X25-E
End exit
Installation Instructions
Mounting Instructions
Mount on a DIN Rail
1. Hook the DIN rail clip on the bottom of the DF-G2
over the edge of the DIN rail (1).
2. Push the DF-G2 up on the DIN rail (1).
3. Pivot the DF-G2 onto the DIN rail, pressing until it
snaps into place (2).
Mount to the Accessory Bracket
1. Position the DF-G2 in the SA-DIN-BRACKET.
2. Insert the supplied M3 screws.
3. Tighten the screws.
Remove from a DIN rail
1. Push the DF-G2 up on the DIN rail (1).
2. Pivot the DF-G2 away from the DIN rail and remove
it (2).
2 Custom fiber arrays and mounting configurations are possible. Consult factory for assistance with your small object counting
application.
3 With 2% threshold offset percentage
DF-G2 High Speed Expert
™
Dual Display Small Object Counter
2
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 178061 Rev. E