![Banner DF-G1 Expert Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/banner/df-g1-expert/df-g1-expert_manual_3756037009.webp)
For Sales and Support, Contact Walker EMD • Toll-free: (800) 876-4444 • Tel: (203) 426-7700 • Fax: (203) 426-7800 • www.walkeremd.com
Dynamic TEACH
• Teaches on-the-fly
• Establishes a single switching threshold
• Threshold can be adjusted using “+” and “-” rocker button (Manual Adjust)
Dynamic TEACH is best used when a machine or process may not be stopped for teaching. The sensor learns during actual sensing
conditions, taking multiple samples of the light and dark conditions and automatically setting the threshold at the optimum level (see
Figure below).
Sensor positions
threshold midway
between taught conditions
Darkest
(no signal)
Most Light
(saturated
signal)
Output OFF
Output ON
Darkest Taught
Condition
Lightest Taught
Condition
Position
adjusted by
Manual Adjust
Figure 6. Dynamic TEACH (Light Operate shown)
The output ON and OFF conditions can be reversed using the LO/DO switch (see LO/DO Switch in
Dynamic TEACH and Manual Adjust
• Moves switching threshold value up or down to make adjustments
• Slide Mode switch to ADJ to enter Adjust mode
• Press “+” to increase; press “-” to decrease
• GREEN display shows the switching threshold value
• 2 seconds after adjustment, GREEN display will flash 3 times to confirm
• Slide Mode switch to RUN to complete operation
Remember: Manual adjustments are disabled when Auto Thresholds are ON
DF-G1 - Expert Dual Display Fiber Amplifier Manual
P/N 161999 Rev. A
www.bannerengineering.com - tel: 763-544-3164
9