background image

Accessories

Quick Disconnect Cordsets

6-Pin Snap-on M8/Pico-Style Cordsets
Model

Length

Style

Dimensions

Pinout

PKG6Z-2

2 m (6.5 ft)

Straight

ø10 mm max.

(0.4")

28 mm max.

(1.1")

3

2

4

5

6

1

1 - brown

2 - white

3 - blue

4 - black

5 - pink

PKG6Z-9

9 m (30 ft)

PKW6Z-2

2 m (6.5 ft)

Right-angle

20 mm

(0.8")

25 mm max.

(1.0")

ø12 mm max.

(0.5")

PKW6Z-9

9 m (30 ft)

DIN Rail Accessories

SA-DIN-CLAMP

• Pair of metal DIN rail end stops; slide onto DIN rail at either

side of sensor stack; holds bussable power models together to

maintain electrical connection

• Combination (#2 Phillips, #8 standard slotted) set screw

9.1 mm 

(0.36")

9.1 mm 

(0.63")

45.0 mm 

(1.77")

SA-D10B-CAP

Package of 5 each replacement terminal caps and plugs to cover beginning and end of stack of connected sensors.

Banner Engineering Corp Limited Warranty

Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of

shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned

to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse,

abuse, or the improper application or installation of the Banner product.

THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (IN-

CLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND

WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.

This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. 

IN NO EVENT SHALL

BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPEN-

SES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY

PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WAR-

RANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.

Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or

liabilities relating to any product previously manufactured by Banner Engineering Corp.

 

 

D10 Expert Series with Bar Graph Display and Discrete Output

 

www.bannerengineering.com - tel: 763-544-3164

 

Содержание D10 Expert Series

Страница 1: ...ription Cable Outputs Red Beam Green Beam D10BFP D10BFPG Standard sensor 2 m 6 5 ft Cable Bipolar NPN PNP D10BFPQ D10BFPGQ 6 pin Pico style QD Models with Bussable Power D10B5FP Main unit 2 m 6 5 ft C...

Страница 2: ...ion Remote Configuration The remote configuration function may be used to configure the sensor remotely or to disable the push buttons for security Connect the gray wire of the sensor to ground 0V dc...

Страница 3: ...ready for 1st TEACH condition Power LED OFF Output LED ON Status LEDs LO DO alternately flashing Bar graph OFF TEACH Output ON Condition Present Output ON condition Click Static button Present Output...

Страница 4: ...reliability 2 to 3 Low Minor sensing variables may affect sensing reliability 1 Unreliable Consider an alternate sensing scheme When Dynamic TEACH mode is used the output ON state Light or Dark Operat...

Страница 5: ...size of the window The lighted LEDs on the light bar separate to a greater or lesser ex tent to exhibit the relative sensing window size Sensor positions window thresholds 100 counts from the present...

Страница 6: ...ight Operate shown Light SET and Light Dark Operate Selection In Light Operate mode Light Set teaches the Output ON condition In Dark Operate mode Light Set teaches the Output OFF condition Push Butto...

Страница 7: ...k Set Light Operate shown Dark Set and Light Dark Operate Selection In Light Operate mode Dark Set teaches the Output OFF condition In Dark Operate mode Dark Set teaches the Output ON condition Push B...

Страница 8: ...ble pulse remote line T T T Power LED OFF Output LED remains active Icon continue to display current setup Static LEDs OFF Select Setting Combination Click either push button until LEDs show desired s...

Страница 9: ...ring with the sensor configuration settings 1 Connect the sensor s gray wire 2 Four pulse the remote line to enable or disable the push button The sensor toggles between enable and disable settings an...

Страница 10: ...tion Protected against output short circuit continuous over load transient over voltages and false pulse on pow er up Output Response Time 500 microseconds normal mode or 200 microseconds high speed m...

Страница 11: ...mm 100 mm 5 mm 10 mm 15 mm DISTANCE BEAM WIDTH BEAM WIDTH Green Beam Models Opposed Mode Diffuse Mode Performance based on 90 reflectance white test card 1 10 100 1000 E X C E S S G A I N DISTANCE 1...

Страница 12: ...39 15 2 mm 0 60 2x C sink 8 0 mm 0 31 3 2 mm 0 13 deep 4 4 mm 0 18 thru 2x 3 5 mm 0 14 5 0 mm 0 20 8 6 mm 0 34 25 4 mm 1 00 16 0 mm 0 63 2 x 3 3 mm 0 13 2x 3 2 mm 0 13 2 5 mm 0 10 5 0 mm 0 20 M3 Hardw...

Страница 13: ...have been defective during the warranty period This warranty does not cover damage or liability for misuse abuse or the improper application or installation of the Banner product THIS LIMITED WARRANTY...

Отзывы: