Banner AG4 Series Safety Laser Scanner
AG4-PCD9-RA
82154
3082154
Plug & socket 9 pin AG4 for X2 interface cable routing to rear
AG4A-SW-A
144088 144088
Configuration
and diagnostics software, AG4soft ( Windows 95/98/2000/NT/XP)
2.2
Specifications
Supply Voltage (UB)
24 V DC (+20% / -30%)
Power supply in acc. with IEC 742 with safe supply isolation and compensation with voltage dips of up to 20 ms in
acc. with EN 61496-1.
Over current protection:
Via 1.6 A fuse melting fuse in the cabinet
Current consumption:
Current consumption:
10 W with 24 V plus output load
Over-voltage protection:
Over-voltage protection with safe limit stop
Protective earth conductor:
Connection not permitted
Supply Current
Approx. 420 mA (use 2.5 A power supply)
Fuse (power supply)
1.6A normal blow, medium time lag fuse
Response Time
Min. 80 milliseconds (2 scans)
Max. 640 milliseconds (16 scans)
Wavelength
905 nm
Protection Zone
150 mm resolution:
200 mm to 4.0 m (radius)
70 mm resolution:
200 mm to 4.0 m (radius)
50 mm resolution:
200 mm to 2.8 m (radius)
40 mm resolution:
200 mm to 2.2 m (radius)
30 mm resolution:
200 mm to 1.6 m (radius)
Sensing object reflectance:
Minimum 1.8%
Warning Zone
Min. object size:
150 mm x 150 mm
Sensing range (radius):
200 mm to 15 m
Sensing object reflectance:
Minimum 20%
Measurement Zone
0-50 m
Scanning Angle
max. 190°
Control Outputs
(OSSD1, OSSD 2)
PNP open-collector transistor 2 outputs:
short circuit proofed
Rated operating voltage:
supply voltage (UB) -3.2 V
Max. source current
: 250 mA
Residual voltage:
3.2 V or less
Operation mode:
No object in detection zone:
ON
Object inside detection zone:
OFF
Response Time:
Min. 80 ms (2 scans) to max. 640 milliseconds (16 scans) switching method
Warning Output 1 (Alarm 1) &
Warning Output 2 (Alarm 2)
PNP open-collector transistor
Rated operating voltage:
supply voltage (UB) -4 V
Max. source current:
100 mA
Residual voltage:
4 V or less
Operation mode:
Switching method of operation mode (set below)
Scanner at normal operation:
ON
Abnormal
operation:
OFF
No object inside warning zone:
ON
Object inside warning zone:
OFF
Response Time:
Min. 80 ms (2 scans) to max. 640 milliseconds (16 scans) switching method
Laser Protection Class
Class 1 (IEC 60825-1)
Number of Field Pair (Zone)
Settings
7 +1 (without detection zone). Zone pairs in combination of detection zone and warning zone can be switched over by
external input
Environmental Rating
IP65 (per IEC 60529)
18
P/N 144924 05/2009
Product Manual