Plasma Display Panel (PDP) pixel test
The PDP pixel test checks the status of the PDP, with regard to the number of defective pixels
The test is used:
- before transporting the product or the PDP to a workshop
- before and after service on the PDP
- Please refer to illustrations for:
- Placement of black self-adhesive tape on the PDP
- Placement of buttons on NN Remote control
- Remove front frame and front cloth.
See illustrations, page 6.33.
- Remove the black self-adhesive tape on the PDP. See
➢
4.
- Switch on the product.
- Enter service mode, CAT Panel menu.
Press and hold button B and at the same time press button C 3 times within 1 second.
See
➢
4 and
➢
5.
- Select
Aging.
Place the cursor on IIC Mode and press “OK”.
Select
“Aging”, use the up/down arrow buttons to step through the pictures on
the on-screen-display.
Press
“OK” to activate the internal test pictures.
Press
“OK” to switch between the different test pictures.
- PDP Pixel test.
Use
the
“GREEN”, “RED” and “BLUE” test picture for checking the pixels.
- Exit Service mode.
Press R twice to return to CAT Panel menu.
Press C to exit the service mode.
B
LED
➢
4
➢
5
6.12 Plasma Display Panel pixel test, English
C
+
+
_
VOL
R
R
OK
Содержание BeoVision 5-42 US
Страница 1: ...BeoVision 5 42 US Type 8489 Service Center repair guide English Spanish...
Страница 12: ...3 1 Wiring diagram Wiring diagram 3 1 3 1 Wiring diagram...
Страница 39: ...5 16...
Страница 55: ...5 32...
Страница 96: ...2x 21x 4x 1 2 3 4x Plasma Display Panel in service position 6 35...
Страница 98: ...C1 SS F SSP34 C1P24 2x 19x Remove contrast screen and plasma frame Remove contrast screen and plasma frame 6 37...
Страница 111: ...6 50...