Fault flow chart 2.5
Fault symptom:
- No stand-by light
- Unable to use/remote BS4
Possible causes:
- PCB6, SMPS
- Fuse F0
Measure mains supply
Fuse F0 OK?
Replace defect fuse
Connections from
PCB6 to other
boards OK?
Re-create connection
Replace PCB6, SMPS
Fault symptom:
- No sound in headphone
Possible causes:
- PCB9, headphone connector
- PCB2, Master
Unplug headphone
Sound in speaker?
Switch to FM
Sound in speaker?
Change PCB2, Master
Plug another
headphone
Sound in headphone?
Connection from
PCB2 to PCB9 OK?
Re-establish
connection
Change PCB9,
Headphone
No
Yes
Change PCB2, Master