Replace
The
replace
function in ServiceTool is used when it is not possible to perform a
Backup/Restore of the module.
Connect ServiceTool, launch
BeoLab 17
and follow the procedure under
Repair
->
Chassis.
Connecting speaker wirelessly
After replacement of PCB89, Wireless Power Link Rx the speaker must be set up in
the wireless system correctly. Depending on the setup, there will be a few settings.
Setup with BeoLab Transmitter 1:
- Press the
RESET
button on the speaker (set speaker in associate mode)
- Press
SELECT
and
STORE
simultaneously between 1.5 and 10 seconds to reset
association on the BeoLab Transmitter 1
- Press
SELECT
to make a rescan on BeoLab Transmitter 1
Setup with product equipped with Wireless Power Link Tx:
- Press the
RESET
button on the speaker (set speaker in associate mode)
-
Delete
speaker in menu of the product equipped with Wireless Power Link Tx
- Perform a
rescan
in menu of the product equipped with Wireless Power Link Tx
Speaker units
Calibration of speaker driver
Calibration of speaker driver is necessary when a speaker unit is replaced. The aim
is to ensure optimal sound even if the new speaker unit varies from the old
speaker unit. Use the
read
function to enable the calibration data fields.
Connect ServiceTool, launch
BeoLab 17
and follow the procedure under
Adjustments -> Speaker calibration.