2. Remote control of d&b amplifiers
The PP15 allows remote control of the following objects by recalling a
dedicated preset.
–
AmpPresets
–
Standby mode
–
Mute
–
Level control from –57.5 dB to +6 dB with 0.5 dB detents
–
Delay ON/OFF
–
Delay settings
–
Filter (CUT, HFA, ...)
–
Equalizer ON/OFF
–
Locking "Secondary Masters" (e.g. PC with R1 Remote control
software)
2.1
Error monitoring
The PP15 polls all registered amplifiers for errors at cyclical intervals. If
an error occurs in one of the devices, it is displayed on the error page
of the PP15 with an error number and indicated as a general error
message at the"Error" digital output. In addition an error description in
plain text can be requested. If an amplifier does not respond to the
periodic polls, a "PWR/Comm. Loss" error is displayed and also
indicated as a general error message at the “Error” digital output.
2.1.1
Error numbers for D12, D6, and E-PAC
Device Errors
No
Remark
0
OK
1
System Error
2
Program Error
3
PS Overtemp.
4
PS Overvoltage
5
PS Undervoltage
6
PS Temp. Warn.
7
PS Error
8
DSP Error
9
Remote Error
B&R PLC PP15 for use with the, d&b Remote network, Reference manual (1.1 EN)
Page 5 of 16