Technical data • Individual components
86
Panel PC 800 User's Manual V1.30
Product ID
5AC801.HDDI-00
Positioning time
Minimum (track to track)
1 ms
Nominal (read only)
12.5 ms
Maximum (read only)
23 ms
Environmental conditions
Temperature
3)
Operation
4)
-30 to 85°C
24-hour operation
5)
-30 to 85°C
Storage
-40 to 95°C
Transport
-40 to 95°C
Relative humidity
6)
Operation
5 to 90%, non-condensing
Storage
5 to 95%, non-condensing
Transport
5 to 95%, non-condensing
Vibration
Operation
5 to 500 Hz: 2 g; no unrecoverable errors
Storage
5 to 500 Hz: 5 g; no unrecoverable errors
Transport
5 to 500 Hz: 5 g; no unrecoverable errors
Shock
Operation
300 g and 2 ms duration; no unrecoverable errors
150 g and 11 ms duration; no unrecoverable errors
Storage
800 g and 2 ms duration; no unrecoverable errors
400 g and 0.5 ms duration; no unrecoverable errors
Transport
800 g and 2 ms duration; no unrecoverable errors
400 g and 0.5 ms duration; no unrecoverable errors
Altitude
Operation
-300 to 5000 m
Storage
-300 to 12192 m
Mechanical characteristics
Installation
Fixed
7)
Dimensions
Width
13 mm
Height
98 mm
Depth
105 mm
Weight
134 g
Manufacturer information
Manufacturer
Seagate
Manufacturer's product ID
ST940817SM
Table 65: 5AC801.HDDI-00 - Technical data
1)
Yes, although applies only if all components installed within the complete system have this certification
2)
With 8760 POH (power-on hours) per year and 70°C surface temperature.
3)
Temperature values at an elevation of 305 meters. The temperature specification must be reduced linearly by 1°C every 305 meters. The temperature
increase and decrease can be a maximum of 20°C per hour.
4)
Standard operation refers to 333 POH (power-on hours) per month.
5)
24-hour operation refers to 732 POH (power-on hours) per month.
6)
Humidity gradient: Maximum 15% per hour.
7)
Slide-in compact installation.
3.9.1.4 Temperature humidity diagram
Temperature [°C]
R
el
at
iv
e
hu
m
id
ity
[%
R
H
] (
no
n-
co
nd
en
si
ng
)
Operation
St
or
ag
e
/ T
ra
ns
po
rt
Figure 30: 5AC801.HDDI-00 - Temperature humidity diagram