Installation and connection • Connecting and disconnecting the motor
Chapter 5 Installation
and connection
8JSA user's manual V1.00
79
Warning!
Risk of burns due to hot surfaces!
Touching hot surfaces (e.g. motor and gearbox housings, as well as connected components), can lead
to very severe burns due to the very high temperature of these parts.
•
Do not stay in the danger zone during operation and secure it against access by unauthorized
persons.
•
Never touch the motor or gearbox housing as well as adjacent surfaces during nominal load
operation.
•
Be aware of hot surfaces also during downtime.
•
Allow motor and gearbox to cool sufficiently before working on it. This is because there is still
a risk of burning for a prolonged period of time even after shutting down.
•
Always operate the motor or gearbox with all safety devices. Do this even during short testing
and trial operations!
5.1 Cables and connectors
Information:
To find the technical data and order data for the cables, see the current user's manual for the B&R
drive system being used.
They are available in the Downloads section of the B&R website (
5.1.1 Cables from other manufacturers
Caution!
Damage caused by voltage rise!
Cables from other manufacturers can have a negative effect on voltage rise on the winding. The winding
can become damaged as a result of voltage rise.
•
If non-B&R cables are used, you must provide documented evidence of conformity with voltage
class A per EN 60034-25.
•
If this evidence has not been provided, there is no claim to warranty due to winding damage
that can be attributed to a rise in voltage on the winding.
5.1.2 Connectors from other manufacturers
Note:
Disturbances caused by electrical or electromagnetic effects!
When using connectors from other manufacturers, EMC faults cannot be excluded.
•
Use B&R connectors to ensure compliance with the EMC limit values of the connection.
•
Ensure proper assembly and that cable shields are connected correctly.
5.1.3 Cable clamp and bend radius
To ensure that cables and connectors are not exposed to harmful loads, the cable clamp
(A)
and minimum bend
radius
(R)
must be observed during installation.