B&R Industries REVERSE OSMOSIS Скачать руководство пользователя страница 4

HOW YOUR REVERSE OSMOSIS SYSTEM WORKS

Your Reverse Osmosis System is completely self contained and uses stages for primary filtration and 
separations.

FIRST STAGE: Prefilter

The prefilter protects the reverse osmosis membrane from clogging by removing suspended and particulate
matter larger than approximately 5 microns.

The life of the prefilter depends upon the quality of the incoming tap water. Generally, we recommend 
replacing every six to twelve months. Please see the directions for changing filters on page 5.

Model VI-TFC: Recommend replacing every 12 months
1-5 Micron sediment prefilter
1-Carbon prefilter 
1-Carbon postfilter

Model VII-TFC: Recommend replacing every 12 months
1-5 Micron sediment prefilter
2-Carbon prefilter 
1-Carbon postfilter

SECOND STAGE: Reverse Osmosis Membrane

The R.O. membrane is the heart of the system. This is where most of the dissolved solids and remaining 
impurities are filtered and flushed out the drain.

The life of the R.O. membrane depends greatly upon the quality of the incoming water source. Having a soft
water supply will greatly increase its life expectancy. The membrane should be changed when it rejects less
than 60% of dissolved minerals.

Call your dealer for information on monitoring devices or water check programs.

THIRD STAGE: Activated Carbon Postfilter

The carbon postfilters function is to reduce tastes, odors, and chlorine, and is the final stage of filtration. It
should be replaced every 12 months. See the directions for changing filters on page 5. 

4

Содержание REVERSE OSMOSIS

Страница 1: ...NER S MANUAL MODEL ___________ REVERSE OSMOSIS KING WATER SYSTEMS ealer ________________________ No ______________________...

Страница 2: ...e Please take the time to carefully review this manual To realize your system s maximum performance you should become familiar with your system and how Reverse Osmosis works Warning This Reverse Osmos...

Страница 3: ...house is turned off or if you are gone more than 1 month you must remove the R O membrane to protect it from drying out Remove entire membrane module housing wrap in plastic and store in refrigerator...

Страница 4: ...mmend replacing every 12 months 1 5 Micron sediment prefilter 2 Carbon prefilter 1 Carbon postfilter SECOND STAGE Reverse Osmosis Membrane The R O membrane is the heart of the system This is where mos...

Страница 5: ...rane housing open water supply valve and flush filters for 2 3 minutes or until water turns clear Reconnect yellow line going to the membrane housing and turn on inlet and tank valve CHECK FOR LEAKS P...

Страница 6: ...rap to prevent dripping sound Drill hole and position drain saddle hole and gasket over the hole drilled in pipe Note If the hole in the pipe and the hole in the drain saddle are not lined up the RO w...

Страница 7: ...7...

Страница 8: ...8...

Страница 9: ...9 must be cut to allow direct gravity feed to drain...

Страница 10: ...Screen or flow control assembly plugged 5 Membrane fouled Replace membrane module Contact your local dealer Carbon prefilter may be exhausted Replace with new cartridge Replace check valve tee Contact...