Bandit
28
Copyright 9/18
MODEL 15XP/1390
LOR Jumper Plug
Part No.: 900-2913-51
IEC Jumper Plug
Part No.: 900-2914-09
TROUBLE SHOOTING GUIDE cont.
Autofeeds with dump blocks can be unplugged and run manually. Autofeeds with dual output
block will need a jumper plug. This can be a good test to determine if you problem is hydraulic or electronic.
NOTICE
PROBLEM
POSSIBLE CAUSE
SOLUTION
Feedwheels Run
In Reverse From
Normal
-Backup time set wrong.
-Reset backup time. Normal setting is 180 milliseconds
(139 for Models 12XPC/12XP/15XP/95/990) (IEC) or
.3 seconds (LOR)
-Sticking reverse valve.
-Check solenoid operation.
-Override cartridge manually by sticking a small
allen wrench in the end of the solenoid.
-Replace solenoid and/or cartridge.
Type settings programmed
wrong.
-Reprogram or consult local dealer or Bandit Ind
APPROXIMATE DIGITAL AUTOFEED SETTINGS
(FOR ALL AUTOFEED SYSTEMS - REFERENCE ONLY)
Refer to the Completion/Check Sheet, that is shipped with the machine for the correct engine
rpm. If needed, contact your local dealer or Bandit Industries.
NOTICE
AUTOFEED OPTIONS
Some Current Engine Types
Maximum
RPM
PPR
Off
RPM
On
RPM
Feed Reverse
Time
GM 4.3 - 130 Hp
2600
2
2400
2150
180 / .3
GM 5.7 - 165 Hp
2800
2
2700
2400
180 / .3
CAT C3.4 / Perkins 854F - 74 Hp
2200
N/A
2100
1750
180 / .3
CAT C4.4 / Perkins 1104D - 97 Hp
2375
126
2280
2030
180 / .3
CAT C4.4 / Perkins 1104D - 114 Hp
2375
126
2280
2030
180 / .3
CAT C3.4 / Perkins 854F - 112.5 Hp
2200
N/A
2100
1750
180 / .3
Содержание INTIMIDATOR 15XP/1390
Страница 19: ......
Страница 37: ...Bandit 23 Copyright 9 18 MODEL 15XP 1390 DECALS...
Страница 38: ...Bandit 24 Copyright 9 18 MODEL 15XP 1390 DECALS...
Страница 156: ...Bandit 140 Copyright 9 18 MODEL 15XP 1390 SERVICE RECORD SERVICE RECORD DATE DESCRIPTION AMOUNT...
Страница 181: ...BANDIT CONTROLS 25 245774458290 21Dec2016 Document notes 21Dec2016 First Draft...