Bandit 240 PB Скачать руководство пользователя страница 1

Introduction 

........................................................................................................page 01

Safety precautions 

......................................................................................................03

Mounting 

......................................................................................................................05

Electrical connection

......Main power..........................................................................

PCB layout  .........................................................................09
Inputs...................................................................................10
Outputs................................................................................22

Status communication 

...Front LEDs...........................................................................32

Audio ...................................................................................35

Event-log 

......................................................................................................................37

Passwords

  ...................................................................................................................38

Control Box  

................................................................................................................39

HY3-pack replacement  

...............................................................................................41

Maintenance

.................................................................................................................43

First aid  

.......................................................................................................................44

Schematic examples

  ...............................................45

Specifications 

..............................................................................................................04

08

Frequently asked questions & 

BANDIT

 240PB Installation manual 

v.408

World leader in
active security

INSTALLATION MANUAL

    ONTENTS

BANDIT 

240PB

C

UK 230 VAC

Содержание 240 PB

Страница 1: ...us communication Front LEDs 32 Audio 35 Event log 37 Passwords 38 Control Box 39 HY3 pack replacement 41 Maintenance 43 First aid 44 Schematic examples 45 Specifications 04 08 Frequently asked questio...

Страница 2: ...objects by doing so burglary damage is effectively limited to a strict minimum Advantages Fills 1000 Ft 28 m of space per second of fog expulsion Extremely compact and discrete design A system free of...

Страница 3: ...ffers a friendly Windows like users program It is advised to perform a yearly fog generator test See also Maintenance page 43 Standards Complies with European CE and EMC Standards Complies with Intern...

Страница 4: ...main supply fuse to off In case of doubt immediately contact your BANDIT dealer or manufacturer mentioned on the back cover of this manual There are no repairable components inside the appliance Leave...

Страница 5: ...ce second with 1 Ft eye object 230 PSI 1 6 Mpa 18 seconds 50 minutes from cold condition maximum 50 C 120 F and minimum 0 C 30 F 40 W hour 18 kW hour section 0 000016 In 0 004 mm full aerosol 1 4 litr...

Страница 6: ...point in the direction of fragile objects The powerful fog expulsion could blow down these objects There has to be a free passage area for the ejected fog of at least 20 Ft before it bounces against a...

Страница 7: ...it with included double sided adhesive tape The device is installed at 2 In 50 mm off the floor to avoid possible damage due to cleaning tools or water Hidden mounting of the appliance For installatio...

Страница 8: ...980 Ft Fog image after 8 sec of fog expulsion The BANDIT 240 has a room filling capacity of 1000 Ft per second This corresponds with 100 Ft sec The max surface area which can be secured with one devic...

Страница 9: ...al is warned Connection on the main power supply on the left beneath the PCB you ll find a 3 way terminal block with integrated main fuse The PCB is marked with 230 VAC supply Connect the left connect...

Страница 10: ...input n 1 12 VDC supply max 500 mA Mains power supply connection block with integrated fuse 4 AT Mains power connecting cable min 1 5 mm 12 V c c c c c c Supply Xin1 Xin2 Xin3 Xin4 Tmpout OKout OKout...

Страница 11: ...nal source or from the 12 V BANDIT supply source itself Supply the input current with 12 V is 10 mA each input each input is equipped with a Schmitt input after the opto coupler The trigger voltage is...

Страница 12: ...operties of the guard mode 4The red LED Guard on the front panel will be on as long as the unit is in guard mode 4Eventual LED warnings on the front panel such as failure HY 3 and power Will be off un...

Страница 13: ...vate the alarm mode through a negative or a positive edge F F If the optional remote control is connected channel 1 and or 2 can be set as additional alarm input s Using the software additional option...

Страница 14: ...determined with the function of doorbell output this output will be active as long the doorbell audio signal is heard Activation of the door bell input 4While the unit is switched into guard mode Dep...

Страница 15: ...he unit will sound The volume as well as the sounding period of this panic siren can be set speaker panic siren Activation of the panic input Depending on the software settings this input can start or...

Страница 16: ...system is still in guard mode Properties of the warning mode 4If the function of an output is determined as warning output this output will be active as long as the warning mode is activated 4The mome...

Страница 17: ...ending on the software settings this input can start the fire alarm mode when A negative or a positive voltage edge pulse an active puls will switch on the fire mode Following pulses have no influence...

Страница 18: ...hed onto the fire alarm mode and an eventual active fire alarm mode will be interrupted 4A fire alarm off input can only be selected when there is also a fire alarm on input selected 4The switching of...

Страница 19: ...d relay contact in serial with the existing tamper relay circuit Tmpout In high risk installations the fixed defined output Tmpout is integrated in the tamper circuit of the existing alarm system If i...

Страница 20: ...g as the internal siren input is active but the internal Bandit electronics will reduce the audio volume after 3 minutes of sounding to 50 battery saving Activation of the internal siren input Only vo...

Страница 21: ...l control is possible Depending on the software settings 0 V or 12 V can be set as active 4The internal siren will sound 4The time of activation as well as deactivation of this input will be logged 4I...

Страница 22: ...cation until 10 seconds after the last communication signal If this Led blinks both batteries have to be replaced Sony CR2430 or compatible Yellow Led RS 232 communication Led Blinks simultaneously wi...

Страница 23: ...ricted by F2 In normal conditions and with a full charged battery under charging current the voltage is 13 volt This voltage is practically ripple free 5mV ripple and serves as supply for small extern...

Страница 24: ...See p 18 Based on the info of these different inputs the MCU software will decide whether to activate or not to activate the Tmpout relay Properties of the tamper mode The Tmpout relay is in rest pos...

Страница 25: ...re gives you the possibility to bridge the HY 3 pack side hatch tamper contact e g when opening this hatch to change the HY 3 pack without causing a tamper alarm 7 BS software HY 3 pack R Software HY...

Страница 26: ...fuse F3 6 3 A battery fuse is interrupted 4There is no battery or the voltage of the battery is too low 4The ambient temperature of the mounted HY 3 pack exceeds 120 F 4The heat exchanger can not rea...

Страница 27: ...g Demo HY 3 pack in a regular device Tamper contact of the side hatch is bridged through the control box switch and or through software R HY 3 pack screen As soon as the internal failure is restored...

Страница 28: ...ned trough software settings Max 500 mA 12 V t ol 0 V 12 V MCU Relais 12 V 1 A c c Xout com nc nc no no Block scheme BANDIT programmable outputs No function The output is always in rest position and i...

Страница 29: ...it is as efficient as a visible outer siren For the owner it is a clear sign that BANDIT is in guard mode Function as long as BANDIT is in guard mode this Jumbo LED will blink 1 Hz A maximum of three...

Страница 30: ...re is selected a warning input see page 15 it will be possible to select also a warning output The output follows always the status of the warning mode This output is used to extend the warning audio...

Страница 31: ...t clicked on The output will be active as long as the guard on beep lasts but will be in rest when the guard off beep sounds Only Doorbell sound is clicked on This output can only be activated COM and...

Страница 32: ...ble power supply failure is a very important function The solution for this eventual power supply failure is often the responsibility of the enduser while a battery problem is the responsibility of th...

Страница 33: ...power supply is present the unit needs approximately 50 minutes from cold condition to reach its target temperature If BANDIT is in guard mode This green LED will be on This way the unit will never re...

Страница 34: ...terrupted back to factory the internal 12 V charging voltage normally 13 1 13 2 V is too low If the main power supply is present BANDIT will perform a battery condition test each time the guard or bac...

Страница 35: ...ossibility which automatically turns off the 4 s after the unit is put into guard mode 7 BS software Settings Edit Frontpanel The will regain their normal functionality from the moment the unit is put...

Страница 36: ...o circuit The available signals are compiled into the flash memory of the MCU The preferred cy is presented through a high low and a digital potentiometer volume controller to the a u amplifier This o...

Страница 37: ...at the unit is refusing to switch into the requested guard mode Usually this means that the moment the unit is put into guard mode one or more alarm inputs were already activated This could result imm...

Страница 38: ...d disk in the directory pb240 events The file name of the saved file is generated automatically for example 2004_09_15__00_11_27 pdf This name exists out of the date time plus eventual device alias ti...

Страница 39: ...ndit Change password installer password By entering first the actual valid old password the software will request the new password The BS software controls in real time the validity of the entered pas...

Страница 40: ...d finished with a general insulation over the complete wire In the packing of the Control Box you ll find the mounting screws and nuts also a 6 way plug in connector with screw connection First insert...

Страница 41: ...stays closed so no sabotage notice or fog expulsion while opening the side hatch The green LED on the switch is on The front LED internal failure blinks fast 2Hz This allows a fog ejection test each...

Страница 42: ...olt red allen fixing bolt green HY 3 OK LED HY 3 hatch tamper pin M8 thread hole for HY 3 pack grip tool P 41 Replacement of HY 3 pack If the level seems to have gone below the adjusted minimum value...

Страница 43: ...Y 3 pack connector and the liquid coupling are sliding over their respective connector and coupling Unscrew the HY 3 pack grip and fasten both red allen fixing bolts The green HY 3 pack LED will be on...

Страница 44: ...ejection test is performed you ll have to warn all persons in the immediate surroundings and the responsible person for fire hazard Make sure no one is looking at the direction of the ejection mouth...

Страница 45: ...tly persons who are over sensitive to stressing situations e g hyperventilate racing pulse etc persons who are strong asthmatic or exceptionally sensitive to irritation of the respiratory system child...

Страница 46: ...even though BANDIT is functioning as supposed or if it is malfunctioning due to an internal or external failure We advise the installer to inform his insurance company that they will be installing fo...

Страница 47: ...communication with BANDIT main PCB The purpose of these electronics is to measure how much fluid is present in the pressure vessel and to store all production and filling data of the HY 3 pack If the...

Отзывы: